Electrical connection

Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent per- son.

1 WARNING: THIS APPLIANCE

MUST BE EARTHED.

Should the appliance power supply cable need to be replaced, this must be carried out by a Service Force agent (see page 29).

The manufacturer declines any responsibility should this safety measure not be observed.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance´s rating plate. (See picture on page 5).

The appliance is supplied with a 13amp plug fitted.

In the event of having to change the fuse in the plug sup- plied, a 13amp ASTA approved BS I363/A fuse must be used.

Should the plug need to be replaced for any reason, pro- ceed as described below. The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

 

Green & Yellow

BlueBrown

Cord Clamp

If you fit your own plug, the colours of the wires in the mains lead of your appliance may not correspond with the markings identifying the terminals in your plug.

Proceed as follows:

1.Connect the Green and Yellow (earth) wire to the termi- nal in the plug which is marked with the letter "E" or the earth symbol or coloured green and yellow.

2.Connect the Blue (neutral) wire to the terminal in the plug which is marked with the letter "N" or coloured black.

3.Connect the Brown (live) wire to the terminal in the plug which is marked with the letter "L" or coloured red.

4.Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

1 WARNING:

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.

1 The plug must still be accessible after the ap- pliance has been installed.

1 The appliance should not be connected to the electrical supply by means of an extension ca- ble.

Permanent connection

In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm be- tween the switch contacts and of a type suitable for the re- quired load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.