430645-YIM-D-0610

Nomenclature

Configured Split Condenser Model Number Nomenclature

 

 

P

C

240

C00

A

2

A

AA

2

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Style

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Category

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Style A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P = Split System, Condenser, HP, R-410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Generation

 

 

Product Identifier

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 = First Generation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = Second Generation

 

 

C = Standard Efficiency, 2-Pipe, R-410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D = Standard Efficiency, 4-Pipe, R-410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Options

Nominal Cooling Capacity - MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Options

 

AA = None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AB = Phase Monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

A = None

090 = 7.5 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC = Coil Guard

 

 

 

 

 

 

 

 

 

 

 

 

 

B = Option 1

 

120 = 10 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AE = Phase Monitor + Coil Guard

 

 

 

 

 

 

 

 

 

 

 

 

 

C = Option 2

 

150 = 12.5 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LA = Low Ambient

 

 

 

 

 

 

 

 

 

 

 

 

 

D = Options 1 & 2

 

180 = 15 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LB = Low Ambient + Phase Monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

S = Options 5

 

240 = 20 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LC = Low Ambient + Coil Guard

 

 

 

 

 

 

 

 

 

 

 

 

 

T = Options 1 & 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LD = Low Ambient + Phase Monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Coil Guard

Heat Type & Nominal Heat Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

1 = Disconnect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LE = Low Ambient + Technicoat Cond. Coil

C00 = Cooling Only

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = Non Pwr’d Conv Outlet

 

LF = Low Ambient + Technicoat Cond. Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 = Pwr’d Conv Outlet

 

+ Phase Monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LG = Low Ambient + Technicoat Cond. Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Coil Guard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

LH = Low Ambient + Technicoat Cond. Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Phase Monitor + Coil Guard

 

 

 

 

 

 

 

 

 

 

 

2 = 208/230-3-60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TA = Technicoat Condenser Coil

 

 

 

 

 

 

 

 

 

 

 

4 = 460-3-60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TB = Technicoat Condenser Coil + Phase

 

 

 

 

 

 

 

 

 

 

 

5 = 575-3-60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitor

 

 

 

 

 

 

 

7 = 380/415-3-50

 

 

 

 

 

 

 

 

TC = Technicoat Condenser Coil + Coil Guard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

TE = Technicoat Condenser Coil + Coil Guard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Phase Monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Standard Motor

 

 

 

 

General

These condensing units are designed for outdoor installation on a roof or at ground level. Every unit is completely piped and wired at the factory and is shipped ready for immediate installation. Only the liquid and suction lines to the evaporator coil, the filter drier, the thermostat wiring and the main power wiring are required to complete the installation. Each unit is dehydrated, evacuated, leak tested and pressure tested at 450 psig before being pressurized with a holding charge of refrigerant R-410A for shipment and/or storage.

All controls are located in the front of the unit and are readily accessible for maintenance, adjustment and service. All wiring (power and control) can be made through the front of the unit.

This Split-System (Air Condensing / Heat Pump / Air Handling) unit is one component of an entire system. As such it requires specific application considerations with regard to the rest of the system (air handling unit, duct design, condensing unit, refrigerant piping and control scheme).

Failure to properly apply this equipment with the rest of the system may result in premature failure and/or reduced performance / increased costs. Warranty coverage specifically excludes failures due to improper application and Unitary Products specifically disclaims any liability resulting from improper application.

Please refer to the equipment Technical Guide, Installation Manual and the piping applications bulletin 247077 or call the applications department for Unitary Products @ 1-877-UPG-SERV for guidance.

2

Johnson Controls Unitary Products

Page 2
Image 2
Johnson Controls PD 180 THRU 240, PC090 THRU 240 dimensions Nomenclature, General

PC090 THRU 240, PD 180 THRU 240 specifications

Johnson Controls has long been a leader in the HVAC and building efficiency industry, and the Johnson Controls PC090 THRU 240 and PD 180 THRU 240 series of commercial rooftop units exemplify their commitment to innovation and energy efficiency. These units are designed to provide optimal performance for a wide range of commercial applications, ensuring comfortable indoor climates while maintaining energy savings.

One of the standout features of the Johnson Controls PC and PD series is their advanced cooling and heating capabilities. Both series can operate efficiently across a varied range of capacities, typically from 90,000 to 240,000 BTU/h for the PC series and 180,000 to 240,000 BTU/h for the PD series. This versatility allows users to select the most appropriate unit size for their specific needs, optimizing performance without wasting energy.

The technology behind these rooftop units includes advanced inverter-driven compressors that enable variable-speed operation. This feature allows for precise temperature control, resulting in enhanced comfort and reduced energy usage. The units also integrate smart controls that enable easy monitoring and management, ensuring that the HVAC system can adapt to changes in occupancy or external weather conditions.

Another notable characteristic of the Johnson Controls rooftop units is their robust construction and reliability. Designed for outdoor use, these units can withstand harsh weather conditions while maintaining operational efficiency. They are equipped with corrosion-resistant materials and protective enclosures to prolong the life of the equipment.

The units are also engineered with eco-friendliness in mind, utilizing refrigerants with low global warming potential to minimize their environmental impact. Furthermore, their energy-efficient designs often qualify for various energy incentives, providing businesses an additional return on investment.

Ease of installation and maintenance is another hallmark of the PC and PD series. With a modular design, these units can be easily transported and installed. Maintenance tasks are simplified, allowing facility management teams to perform regular service checks efficiently and effectively.

Overall, the Johnson Controls PC090 THRU 240 and PD 180 THRU 240 series stand out in the commercial HVAC market due to their flexibility, advanced technology, and dedication to energy efficiency and environmental responsibility. These units not only meet modern energy codes but also contribute to a sustainable future with their innovative features and reliable performance.