Nomenclature
Configured Split Condenser Model Number Nomenclature
|
| P | C | 240 | C00 | A | 2 | A | AA | 2 |
| A |
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Product Style |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Product Category |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A = Style A |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P = Split System, Condenser, HP, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Product Generation |
|
| |||
Product Identifier |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 = First Generation |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 = Second Generation |
|
| |||||||
C = Standard Efficiency, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
D = Standard Efficiency, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Product Options | ||
Nominal Cooling Capacity - MBH |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Installation Options |
| AA = None | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AB = Phase Monitor | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| A = None | ||||||||||||||||
090 = 7.5 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
| AC = Coil Guard | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| B = Option 1 |
| |||||||||||||||
120 = 10 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
| AE = Phase Monitor + Coil Guard | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| C = Option 2 |
| |||||||||||||||
150 = 12.5 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
| LA = Low Ambient | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| D = Options 1 & 2 |
| |||||||||||||||
180 = 15 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
| LB = Low Ambient + Phase Monitor | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| S = Options 5 |
| |||||||||||||||
240 = 20 Ton |
|
|
|
|
|
|
|
|
|
|
|
|
|
| LC = Low Ambient + Coil Guard | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| T = Options 1 & 5 |
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LD = Low Ambient + Phase Monitor | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Options |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| + Coil Guard | |||||||||||
Heat Type & Nominal Heat Capacity |
|
|
|
|
|
|
|
|
|
|
|
|
| 1 = Disconnect |
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| LE = Low Ambient + Technicoat Cond. Coil | |||||||||||||||
C00 = Cooling Only |
|
|
|
|
|
|
|
|
|
|
|
|
| 2 = Non Pwr’d Conv Outlet |
| LF = Low Ambient + Technicoat Cond. Coil | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 = Pwr’d Conv Outlet |
| + Phase Monitor | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LG = Low Ambient + Technicoat Cond. Coil | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| + Coil Guard | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage |
| LH = Low Ambient + Technicoat Cond. Coil | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| + Phase Monitor + Coil Guard | ||
|
|
|
|
|
|
|
|
|
|
| 2 = |
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TA = Technicoat Condenser Coil | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
| 4 = |
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TB = Technicoat Condenser Coil + Phase | |||||||||||||
|
|
|
|
|
|
|
|
|
|
| 5 = |
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Monitor | |||||||||||||
|
|
|
|
|
|
| 7 = |
|
|
|
|
|
|
|
| TC = Technicoat Condenser Coil + Coil Guard | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Airflow |
|
| TE = Technicoat Condenser Coil + Coil Guard | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| + Phase Monitor | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| A = Standard Motor |
|
|
|
|
General
These condensing units are designed for outdoor installation on a roof or at ground level. Every unit is completely piped and wired at the factory and is shipped ready for immediate installation. Only the liquid and suction lines to the evaporator coil, the filter drier, the thermostat wiring and the main power wiring are required to complete the installation. Each unit is dehydrated, evacuated, leak tested and pressure tested at 450 psig before being pressurized with a holding charge of refrigerant
All controls are located in the front of the unit and are readily accessible for maintenance, adjustment and service. All wiring (power and control) can be made through the front of the unit.
This
Failure to properly apply this equipment with the rest of the system may result in premature failure and/or reduced performance / increased costs. Warranty coverage specifically excludes failures due to improper application and Unitary Products specifically disclaims any liability resulting from improper application.
Please refer to the equipment Technical Guide, Installation Manual and the piping applications bulletin 247077 or call the applications department for Unitary Products @
2 | Johnson Controls Unitary Products |