Fuel Conversion Procedure

Fuel Conversion Procedure

1.Turn off gas supply to stove.

2.Remove the stove Top Plate.

3.Disengage the two Glass Frame Latches at the top of the firebox. See illustration on page 5. Carefully lift the glass panel up and out of the stove.

4.If installed, remove the Embers and Log Set using care not to damage the fragile log parts.

5.Lift out the Burner Skirt- (Part 40, fig. 52 p.28).

6.Reach under the stove and remove the Air Shutter wingnut from its stud. As you face the right side, it is the one closest to you. See fig. 22.

7.Lift out the Burner Plate: NOTE: There are no screws securing the Burner to the floor of the firebox. Pull the Air Shutter forward and lift the burner together with shutter up and out of the stove as a unit. See fig. 23.

8.Change the Main Burner Orifice. See fig. 24. Using a ½” open ended wrench or deep-well socket remove the burner orifice from its brass elbow housing and replace with the appropriate orifice supplied in the kit. While removing the orifice, use an adjustable wrench to counter-lock the orifice elbow at the back of the firebox as shown in fig. 24a.

9.Replace the Air Shutter with its gasket and push it all the way back to allow replacement of the Burner Plate. Reattach the wingnut to the shutter stem under the stove, but do not tighten. You will set its final position later.

10.Replace the Burner Plate. Engage the burner tube with the Air Shutter assembly as in fig. 25. Be sure the burner is securely engaged with the two support brackets at the front of the firebox and push the plate back toward the rear of the firebox. When correctly positioned, there will be 1/2” (13 mm) clearance between the burner plate and the front of the firebox. See fig. 25.

11 . CHANGE THE PILOT ORIFICE: From within the firebox, remove the Pilot Head by pulling it straight up from the pilot base. See fig. 26. Using the 4 mm hex key included with the kit, unscrew the pilot orifice (counter- clockwise). Replace with the appropriate orifice:

12.Tighten orifice into the base of the pilot assembly. To prevent bypass leaks, be sure the orifice is secured tightly and flush with the base. Replace pilot head by pushing it down onto the pilot base.

13.Replace the Variable Regulator. Using a Torx T-20 screwdriver, remove the three screws from the front of the valve regulator. See fig. 27.

14.Remove the Regulator Tower, Gasket, white plastic disk, and Spring. Remove the black rubber gasket from the valve. See fig. 27.

Air Shutter

Burner Plate

Figure 23. Remove the Air Shutter and Burner as a unit.

Burner Orifice

Figure 24. Change the Burner Orifice.

Figure 24a. Counter-lock the orifice elbow while removing the burner orifice.