Wall Thermostat Installation
Use Jøtul Thermostat #129706 or a 750 millivolt DC
The thermostat should be connected to the GI425 using a minimum of 16 gauge wire with a maximum length of 35 feet of wire.
Connect the two thermostat wire leads to the two lower terminals on the terminal block located to the right of the ON/OFF/T’STAT switch. Do not overtighten the connections. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER WIRES. See Figure 16.
At the thermostat, the two wires should be connected to the two connections screw on the thermostat base plate per the manufacturer’s instructions.
For thermostatic function, place the
Remote Control
The optional Jøtul Remote Control can be installed on the GI425 gas fireplace. Using the wire supplied with the remote, connect the remote directly to the gas control valve.
Connect one receiver lead to the terminal
labelled TH. Connect the other receiver lead to the terminal labeled TH/TP. DO NOT DISCONNECT ANY OTHER WIRES FROM THE VALVE, AND DO NOT OVER TIGHTEN THE TERMINAL SCREWS.
Place the receiver unit under the control valve on the floor of the fireplace cabinet.
CAUTION:
LABEL ALL WIRES PRIOR TO DIS- CONNECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DAN- GEROUS OPERATION. ALWAYS VERIFY PROPER OPERATION AFTER SERVICING THE APPLIANCE.
ATTENTION:
THERMOPILE
TH
TP
TH
TP
VALVE
TERMINAL
BLOCK
ROCKER
SWITCH
ON
OFF
STAT
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
AU MOMENT DE L’ENTRETIENDES COMMANDES, ETIQUETEZ TOUS LES FILS AVANT LE DEBRANCHEMENT. DES ERREURS DE CABLAGE PEUVENT ENTRAIUN FONCTIONNEMENT INADEQUAT ET DAGEREUX.
Figure 16. GI425 Valve Wiring Diagram
18