Jotul GI 425 DV manual Blower Function, Burner Control, Blower Conrol

Models: GI 425 DV

1 32
Download 32 pages 57.91 Kb
Page 25
Image 25
Burner Control

Burner Control

Manual ON

Blower Function

The blower is controlled by a heat-activated switch (snapstat) that will ONLY function if the blower control switch is in either the HI or LOW setting. The blower will not operate until the sensor reaches 180°F. This will take 15-20 minutes in most installa- tions.

Conversely, once the burner is off, the blower will continue to operate until the snapstat cools down to 140°F and shuts off power to the blower.

If the blower is not needed, place the blower control switch in the OFF position and the snapstat will not function.

CAUTION: Always unplug the Blower when performing any routine service to the GI425 gas fireplace.

Thermostatic

OFF

or STAT Remote Control

Blower Conrol

HI

Blower Function

OFF

and

Speed Control

LO

 

Figure 30a. GI425 Controls - Burner Control and Blower Switch.

25