E320 8.1.x Module Guide

Cables and connectors

Up to four LC-style fiber-optic connectors

(single-mode [ZX] )

Transmit power:

 

 

 

min: –2 dBm

 

 

max: 3 dBm

 

Receive input power:

 

 

min: –22 dBm

 

 

max: –3 dBm

 

See the following corresponding table (ZX Fiber Optic Cabling) for cabling

 

 

requirements.

 

See E320 Hardware Guide, Chapter 5, Cabling the Router for more information.

LEDs

When lit, LED indicates:

 

OK (green)—Physical link is connected properly and is functioning properly

 

FAIL (red)—Failure detected

 

Port LEDs:

 

 

LK (green)—Ethernet link is up

 

 

ACT (green)—Blinks when there is Ethernet traffic being received

Alarms, errors, and events

See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide,

 

 

Chapter 5, Configuring Ethernet Interfaces.

Table 2: SX Fiber Optic Cabling

Fiber Type

Minimal Modal Bandwidth at

Maximum Operating Range (meters)

 

850 nm (MHz*km)

 

 

62.5 microns

160

220

(656.17 ft)

 

200

275

(902.23 ft)

50 microns

400

500

(1640.42 ft)

 

500

550

(1804.46 ft)

Table 3: LX Fiber Optic Cabling

Fiber Type

Nominal Wavelength (nm)

Maximum Operating Range

 

 

(kilometers)

9 microns

1310

10 (6.2 miles)

Table 4: LX40 Fiber Optic Cabling

Fiber Type

Nominal Wavelength (nm)

Maximum Operating Range

 

 

(kilometers)

9 microns

1310

40 (24.85 miles)

20GE-4 IOA

Page 20
Image 20
Juniper Networks E320 manual SX Fiber Optic Cabling, LX Fiber Optic Cabling, LX40 Fiber Optic Cabling, Single-mode ZX