E320 8.1.x Module Guide

Cables and connectors

■

One LC full duplex connector

(single-mode [ZX])

■

Transmit power:

 

 

 

■

min: –2 dBm

 

 

■

max: 3dBm

 

■

Receive input power:

 

 

■

min: –22 dBm

 

 

■

max: –3 dBm

 

■ See the following corresponding table (ZX Fiber Optic Cabling) for cabling

 

 

requirements.

 

■ See E320 Hardware Guide, Chapter 5, Cabling the Router for more information.

LEDs

Board-level LEDs:

 

■ OK (green)—IOA is online and is functioning properly

 

■ FAIL (red)—Failure detected

Port LEDs:

■LK (green)—Ethernet link is up

■ACT (green)—Blinks when Ethernet traffic is being received

Alarms, errors, and events

■

See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide,

 

 

Chapter 5, Configuring Ethernet Interfaces.

Table 6: SX Fiber Optic Cabling

Fiber Type

Minimal Modal Bandwidth at

Maximum Operating Range (meters)

 

850 nm (MHz*km)

 

 

62.5 microns

160

220

(656.17 ft)

 

200

275

(902.23 ft)

50 microns

400

500

(1640.42 ft)

 

500

550

(1804.46 ft)

Table 7: LX Fiber Optic Cabling

Fiber Type

Nominal Wavelength (nm)

Maximum Operating Range

 

 

(kilometers)

9 microns

1310

10 (6.2 miles)

Table 8: LX40 Fiber Optic Cabling

Fiber Type

Nominal Wavelength (nm) Maximum Operating Range

 

(kilometers)

24■ GE-8 IOA

Page 24
Image 24
Juniper Networks E320 manual Max 3dBm