■One LC full duplex connector
■Transmit power:
■min: –8.2 dBm
■max: 0.5 dBm
■Receive input power:
■min: –14.4 dBm
■max: 0.5 dBm
■See the following corresponding table (LR Fiber Optic Cabling) for cabling
requirements.
■See E320 Hardware Guide, Chapter 5, Cabling the Router for more information.
Cables and connectors
(single-mode [LR])
■One LC full duplex connector
■Transmit power:
■min: –4.7 dBm
■max: 4.0 dBm
■Receive input power:
■min: –15.8 dBm
■max: –1.0 dBm
■See the following corresponding table (ER Fiber Optic Cabling) for cabling
requirements.
■See E320 Hardware Guide, Chapter 5, Cabling the Router for more information.
Cables and connectors
(single-mode [ER])
Board-level LEDs:
■OK (green)—Physical link is connected properly and is functioning properly
■FAIL (red)—Failure detected
Port LEDs:
■LK (green)—Ethernet link is up
■ACT (green)—Blinks when there is Ethernet traffic being received
LEDs
■See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide,
Chapter 5, Configuring Ethernet Interfaces.
Alarms, errors, and events
10GE IOA ■27
10GE IOA