One LC full duplex connector
Transmit power:
min: 8.2 dBm
max: 0.5 dBm
Receive input power:
min: 14.4 dBm
max: 0.5 dBm
See the following corresponding table (LR Fiber Optic Cabling) for cabling
requirements.
See E320 Hardware Guide, Chapter 5, Cabling the Router for more information.
Cables and connectors
(single-mode [LR])
One LC full duplex connector
Transmit power:
min: 4.7 dBm
max: 4.0 dBm
Receive input power:
min: 15.8 dBm
max: 1.0 dBm
See the following corresponding table (ER Fiber Optic Cabling) for cabling
requirements.
See E320 Hardware Guide, Chapter 5, Cabling the Router for more information.
Cables and connectors
(single-mode [ER])
Board-level LEDs:
OK (green)Physical link is connected properly and is functioning properly
FAIL (red)Failure detected
Port LEDs:
LK (green)Ethernet link is up
ACT (green)Blinks when there is Ethernet traffic being received
LEDs
See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide,
Chapter 5, Configuring Ethernet Interfaces.
Alarms, errors, and events
10GE IOA 27
10GE IOA