LM-10 Line Module

LM-10 Line Module

Module label

ES2 10G LM

Number of ports

Not applicable

Software release

First supported: 8.0.0

Description

215 W

 

Acts as frame forwarding engines for the physical interfaces

 

Processes up to 10 Gb of data traffic

 

Pairs with ES2–S2 10GE PR IOA and ES2–S1 GE-8 IOA

 

In a SRP-100 configuration, it must be installed in a turbo slot only (slot 2 or slot 4)

 

 

If you install the line module in a slot other than slot 2 or slot 4, it will be disabled

 

 

If you install the LM-10 module next to a configured line module that is already

 

 

installed in slot 3 or slot 5, the LM-10 module will be disabled

 

 

If you install a line module in slot 3 or slot 5 next to a previously installed LM-10

 

 

module, the non-LM-10 module will be disabled

 

In a SRP-320 configuration, it can be installed in any slot

Capability

Supports a line rate of 128–byte frames on IOAs

 

The 100–Gbps switch fabric allocates 3.4 Gbps of overall bandwidth to each regular

 

 

line module slot and 10 Gbps of overall bandwidth to each of the turbo slots (slot 2

 

 

and slot 4).

 

The 320–Gbps switch fabric allocates 10 Gbps of overall bandwidth to each line module

 

 

slot.

 

See JUNOSe System Basics Configuration Guide, Chapter 6, Managing Modules for more

 

 

information.

Software features

Not applicable

Line module compatibility

Not applicable

SRP module compatibility

SRP-100

 

SRP-320

Line module redundancy

Yes (Redundancy IOA must be installed in either slot 0 or slot 11)

compatibility

Can only backup another ES2 10G LM

 

Port redundancy support

Not applicable

Cables and connectors

Not applicable

LM-10 Line Module 9

Page 9
Image 9
Juniper Networks E320 manual LM-10 Line Module