JVC KY-F75 manual DC in terminal Mini DIN 8-pin, female, Lens terminal Metal 12-pin, female

Models: KY-F75

1 52
Download 52 pages 17.03 Kb
Page 13
Image 13

Pin configurations of connectors (continued)

DC IN terminal (Mini DIN 8-pin, female)

 

 

 

7

 

 

 

8

 

 

 

 

 

6

 

5

 

3

 

 

2

4

 

 

1

 

 

 

 

 

 

 

 

 

 

 

Pin no.

 

 

Signal name

1

NC

 

 

 

 

 

 

2

GND

 

 

 

 

 

 

3

NC

 

 

 

 

 

 

4

NC

 

 

 

 

 

 

5

GND

 

 

 

 

 

 

6

12V

 

 

 

 

 

 

7

NC

 

 

 

 

 

 

8

12V

 

 

 

 

 

 

LENS terminal (Metal 12-pin, female)

 

1

10

9

 

 

 

2

 

8

 

3

 

7

 

4

 

6

 

11

5

12

 

 

 

 

 

 

Pin no.

 

Signal name

1

NC

 

 

2

NC

 

 

3

GND

 

 

4

NC

 

 

5

IRIS CONTROL

6

12V DC 400mA max.

7

IRIS POSITION

8

IRIS AUTO /MANU

9 to 12

NC

 

 

CAUTION

Use device whose current consumption is max. 400 mA or less.

REMOTE terminal (Metal 10-pin, female)

Compatible plug:

8

1

HR10A-10P-10P

7

2

(Hirose Electronics)

 

 

 

 

10

9

 

 

6

3

 

 

5

4

 

 

 

Pin no.

 

Signal name

1

 

 

2

TRG IN L active

 

3

NC

 

 

4

FLASH OUT L active

5

 

 

6

NC

 

 

7

NC

 

 

8

GND

 

9

12V output (only when power

 

is supplied from AC adapter)

10

NC

 

 

CAUTION

Consult your JVC dealer concerning the re- mote terminal connection.

Remote cable must use shielded cable. Outer shield of remote cable must to connect 10-pin connector outer metal shell.

Do not input the external trigger during the first 10 seconds after the power is turned ON.

Terminal

I/O

Conditions

name

 

 

2 TRG IN

IN

• Contact point

 

• 3.3V CMOS

recommended

 

• Schmidt Trigger

• Maximum rated

 

Pull-up to 3.3V at

voltage: 5.3V

 

4.7k

• H level: 2.4 ~ 5.0V

 

 

• L level: 0 ~ 0.5V

 

 

• Pulse width:

 

 

Min. 130 ms

4 FLASH

OUT

• Maximum rated

 

• Open collector

current: 150mA

 

 

• Maximum rated

 

 

voltage: 12V

 

 

 

E9

Page 13
Image 13
JVC KY-F75 DC in terminal Mini DIN 8-pin, female, Lens terminal Metal 12-pin, female, Remote terminal Metal 10-pin, female