JVC Model DLA-HX1E manual Replacing the Lamp, The light source lamp and its lamp time

Models: Model DLA-HX1E

1 62
Download 62 pages 48.25 Kb
Page 47
Image 47
Replacing the Lamp

Replacing the Lamp

The light source lamp and its lamp time

The light-source lamp has a service life. The life of lamps currently used for this projector is about 2000 hours. [Average lamp life: 2000 hours]

When the light-source lamp approaches the end of its service life, deterioration progresses rapidly. Please install a new lamp when the accumulated lamp time exceeds 1900 hours or at least get a replacement lamp ready. Depending on the operating conditions, the lamp may have to be changed earlier. If the image remains dark or the tone, unusual, even after adjustment, please replace the lamp as soon as possible. You can check the accumulated used hours of the lamp via the “Lamp time” item in the “Information” menu. (page 40)

Please purchase the new lamp unit from the authorized dealer where you purchased the projector. Exchange lamp Part No.: BHL5006-S

 When lamp time exceeds 1000 hours:

When the accumulated lamp time reaches 1000, a mes-

When the lamp time exceeds 2000 hours:

sage indicating “1000h” will appear on the projected screen.

The lamp indicator on the projector blinks.

• Press [EXIT] button to delete the message.

“Warning” and “Lamp replacement” appear on the screen;

 

 When lamp time exceeds 1900 hours:

the word “Warning” blinks.

• To cancel the message, press the [EXIT] button.

 

When the accumulated lamp time reaches 1900 hours:

However, the same message will appear again every one

The [LAMP] indicator on the projector lights up.

hour.

When the accumulated lamp time exceeds 1900 hours:

Once the lamp time exceeds 2000 hours, and the projec-

tor is either put into the standby state or turned off, pro-

“Lamp replacement” appears on the screen.

jection will not be possible again until the lamp is replaced

* Press [EXIT] button to delete the message.

and the lamp time is reset. (page 49)

 

 

When the lamp time exceeds 2010 hours:

 

The projector quits and shuts down.

 

The [LAMP] and [OPERATE] indicators blink on the projector.

 

The projector does not turn on unless the lamp (lamp unit)

 

is replaced and the lamp time is reset. (page 49)

About lamp replacement

If the projector is set in a constricted place, attempting to replace the lamp in that place could cause injury. Move the projector to a place large enough to work in.

To avoid malfunctions, be sure to use only genuine replacement parts. Also, never attempt to re-use an old lamp as this could cause marked performance deterioration or lamp blow-out leading to projector malfunction. In the worse case, broken pieces of glass from the lamp may cause injuries.

Do not replace the lamp immediately after the projector has been used. The temperature of the lamp unit is still high and could cause a burn. Allow a cooling period of one hour or more before replacement.

Before starting to replace the lamp, disconnect the power cord from the wall outlet while the [STAND BY] indicator is on. Replacing a lamp while the power cord is connected to wall outlet could cause injury or electric shocks.

The procedure for lamp replacement

1. Loosen the screws and detach the light-source lamp cover

• Loosen the two screws with a ª screwdriver.

2.

Handle

Loosen the screws and lift up the handle

• Loosen the two screws with a ª screwdriver.

47

Page 47
Image 47
JVC Model DLA-HX1E manual Replacing the Lamp, The light source lamp and its lamp time, The procedure for lamp replacement