Technical DataVersion 06/05WTC 600 LP / MP

6

Technical Data

 

 

 

 

 

 

 

Parameter

WTC 600 LP

 

WTC 600 MP

 

 

 

Ambient temperature

+1 °C – +50 °C

 

 

 

Storage temperature (upon delivery)

 

to –10 °C

 

 

Humidity

<100 % r.F.

 

 

Supply voltage

3*400 V 50 Hz *

 

 

1*230 V 50 Hz *

Pre-filter controls: prim./sec.

230 V/12 V 50 Hz

 

 

Metering pumps

220 – 240 V 50 – 60Hz

 

 

 

Electrical protection

 

16 A

 

 

 

 

Connected load

2.2kW

 

2.2 kW

 

 

 

 

Effective power consumtion

1.5 kW

 

2.2 kW

 

 

 

 

Minimum temperature of untreated water

 

+5 °C

 

 

 

Maximum temperature of untreated water

 

+35 °C

 

 

 

Reference temperature

 

+15 °C

 

 

 

pH-value of untreated water

 

6 – 9.5

 

 

 

pH-value cleaning agent for cleaning the equipment

 

3 – 11

 

 

 

System intake pressure

 

2 – 6 bar

 

 

Capacity range

15000 l/day (±15 %)

 

 

 

Maximum drinking water supply

 

650 l/h

 

 

 

 

Dimensions: H x W x D

 

 

 

 

 

WTC 600 LP/MP

1800 x 660 x 720 mm

 

 

WTC 600 LP/MP - A

1800 x 1120 x 720 mm

 

 

WTC 600 LP/MP - AM

1800 x 1120 x 720 mm

 

 

 

 

Weight, in delivery condition

 

 

 

 

 

 

WTC 600 LP/MP

 

135 kg

 

 

 

WTC 600 LP/MP - A

 

155 kg

 

 

 

WTC 600 LP/MP - AM

 

175 kg

 

 

 

 

Designed for untreated water based on a

 

 

 

maximum salt content of

2000 ppm

 

5000 ppm

 

 

 

 

 

* depending on supply by the customer