42
English Operating instructions for users KMR 1550 B
nCentre the new filter on the driver (1). Push in the thrust bearing (2). Turn
the thrust bearing clockwise until the stop and fasten with the screws (3).
nInsert the preliminary filter and secure it with the two hand screws.
Setting the Sweeping Pattern
Note:
The main brush can be reset to:
Floating 1: With its deadweight the main brush rests on the floor.
Stationary 2: The sweeping pattern is adjustable at the main brush.
In order to adjust the sweeping pattern reset the main brush to “Stationary”.
nOpen and stay cover
nReset main brush to “Stationary 2
nThe sweeping pattern can be altered by turning the adjusting screw.
To increase coverage – turn screw outwards
or
To reduce coverage – turn screw inwards
nClose the bonnet.
Check the sweeping pattern after making any adjustments.
nDrive the sweeper onto a dusty surface.
nLower the brush roller and let it sweep for several seconds.
nRaise the brush roller and drive the sweeper backwards a short distance
with the bulk waste flap opened.
nThe width of the contact area should be 60 - 80 mm.
Note:
If the sweeping pattern is irregular in shape, arrange for Customer Service to
make the necessary corrections.