Keating Of Chicago 2006 Problem, Probable Cause, Solution, Basket-liftmotor runs, but basket

Models: 2006

1 43
Download 43 pages 21.1 Kb
Page 16
Image 16
Basket-lift motor runs, but basket

Problem

Probable Cause

 

Solution

 

 

 

Basket-lift motor runs, but basket

a. Actuator is faulty.

a. Replace actuator.

does not move.

 

 

 

 

 

 

Basket(s) rise prematurely.

a. Electronic timer is faulty.

a. Replace timer.

 

b. Basket lift relay is faulty.

b. Replace relay.

 

 

 

Spark module flashing.

a. Steady OFF.

a. NO Power or Control Hardware

 

 

Fault.

 

b. Steady ON.

b. Power Applied; Control Okay.

 

c. 1 Flash.

c. No flame sense (current trial

 

 

only). Active until flame sense on

 

 

next trial.

 

d. 2 Flashes.

d. Marginal flame between 1.5mkA

 

 

and 0.5mkA.

 

e. 3 Flashes.

e. Ignition lockout; too many ignition

 

 

failures:

 

 

1. Turn off unit.

 

 

2.

Check incoming gas.

 

 

3.

Spark at electrode.

 

 

4.

Electrode.

 

f. 4 Flashers.

f. Ignition lockout; too many flame

 

 

losses:

 

 

1. Turn off unit.

 

 

2.

Check incoming gas.

 

 

3.

Spark at electrode.

 

 

4.

Electrode.

 

g. 5 Flashes.

g. Control hardware fault detected.

 

 

 

 

14

Page 16
Image 16
Keating Of Chicago 2006 warranty Problem, Probable Cause, Solution, Basket-liftmotor runs, but basket