Kenmore 116.34728, 116.34729 Exhaust Filter, To Remove Primary Filter, ClHning Cam, Slot

Models: 116.34729 116.34728

1 44
Download 44 pages 20.56 Kb
Page 16
Image 16
PRIMARY FILTER

Electrical Shock Hazard

Unplug power cord from electrical

outlet. Do not operate the vacuum cleaner without the primary or

exhaust filters. Be sure the filters

are properly installed to prevent motor fadure and/or electrical shock.

PRIMARY FILTER

Check primary filter frequently and clean when dirty.

TO REMOVE PRIMARY FILTER

Remove the dust bin and dust bin lid

assembly as outlined in the DUST BIN CLEANING section.

While holding

ClHning Cam

pdmary filter

Slot

over a trash con-

Filter

tainer grasp filter,

 

rotate and lift off.

 

Clean primary fil-

Locking Tab

tar by gently tap- Filter Cover ping over a trash

container. Tap on several sides to ensure best cleaning. Rinse with water only as needed, do not use any detergent or soap. Allow the filter to dry for 24 hours before putting it back into the vacuum cleaner.

When cleaning the filter no longer restores vacuum suction to full power you need to replace the filter.

Note: See PARTS AND FEATURES for the filter number.

TO REPLACE PRIMARY FILTER

EXHAUST FILTER

HEPA

The exhaust filter must be replaced when dirty. It should be replaced regularly depending on use conditions.

The filter CANNOT be washed as it will lose its dust trapping ability.

Note: See PARTS AND FEATURES for the filter number.

Remove filter cover by pulling out at the top of the exhaust filter cover.

I I!

Remove the exhaust filter cartridge.

Exhaust

Filter Seal

With slot side on filter towards the filter cover slide cleaning cam

inside opening, rotate filter clock-

wise until slots lock onto tabs in cover.

Cleaning Cam

Slot

Filter

Locking Tab Filter Cover

Push only on filter cartridge frame, not on filter material itself. The foam seal of the

filter should be placed against the vacu- um cleaner body

Note: Under normal use and care, your fil- ter can be expected to last up to 5 years.

Re-assemble dust bin lid to dust bin. Insert into vacuum cleaner and secure with dust bin latch.

Replace the exhaust filter cover by placing bottom tabs in slots and pushing in until cover snaps into place.

16

Page 16
Image 16
Kenmore 116.34728, 116.34729 owner manual Exhaust Filter, To Remove Primary Filter, ClHning Cam, Slot