Filling the Water Heater

Installation Instructions (cont'd)

Filling the Water Heater

_, CAUTIONI

Never use this water heater unlessit is completely filled with water. To prevent damageto the tank, the tank must be filled I with water. Water must flow from the hot water faucet

before turn ng ON gasto the water heater.

To fill the water heater with water:

Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is on the lower front of the water heater.

Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the

water heater and the piping.

Check all new water piping for leaks. Repair as needed.

Venting

_,WARNING

VENT DAMPERS - Any vent damper, whether it is operated thermally or otherwisemust be removed if itsuseinhibitsprop- er draftingof the water heater.

Thermally Operated Vent Dampers: Gas-fired water heaters havingthermal efficiencyin excessof 80% may producea rela- tivelylowflue gastemperature. Suchtemperatures may not be high enough to properly open thermally operated vent dampers. Thiswould causespillage of fiue gasesand may cause carbon monoxide poisoning.

Vent dampers must bear evidenceof certificationas complying with the latest edition of American National Standard ANSI

Z21.68 (ANSi Z21.66 & 67, respectively,cover electricallyand mechanicallyactuatedvent dampers). Beforeinstallationof any vent damper, consultyour localSearsServiceCenter or the gas utilityfor further information.

_ WARNING

To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be utilized. Any additionsor deletions of other gasapplianceson a common vent with this water heater may adverselyaffectthe operation of the water heater. Consult the localSears Service Center or gasutility if any suchchangesare planned.

For proper venting in certain installations, a larger diameter vent pipe may be necessary. Due to great variances in installations, unforeseeableby the manufacturer of the water heater, you must consult your gas company to aid you in determining the proper

venting for your water heater from the vent tables in the latest edi- tion of the National Fuel Gas Code ANSI Z223.1, alsoreferred to

as NFPA 54.

Check the venting system for signs of obstruction or deterioration and replace if needed.

The combustion and ventilation air flow must not be obstructed.

AWARNINGI

Obstructedor deteriorated vent systemsmay presenta seriousI

healthriskor asphyxiation.

[

Place the dra_ hood legs in the receiving holes on the top of

the water heater. The legs will snap in the holes to give a tight fit.

Place the vent pipe over the draft hood. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Secure them together with a sheet metal ;crew.

DRAFT HOOD _

VENT ] I

 

f

[SCRE___I

DRAFT HOOD

VENT TO OUTDOORS

DRAFT HO_

,ORCHIHNEV

AWARNINGJ

The water heater with draft hood installedmust be properlyJ vented to a chimneywhich terminates outtioor_ Never oper- I _e the vraterheater unlessit k ventodte the ootdonrsandhasI adequateair supplyto avoidrisksof improper operation,explo-I

sionor asphyxiation.

]

AWARNING

The vent pipe from the water heater must be no lessthan the diameter of the draft hood outlet on the water heater, and

_€_t-tslope upward to the chimney at least '/4inch per linear

13