Customer Responsibilities

Thank You for purchasing a Sears water heater.

Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new

water heater professionally installed by Sears call the local Sears Service Center or any Sears store. They will arrange for prompt,

quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual

A.G.A. - American Gas Association

A.N.S.I. _ American National Standards Institute

AWARNING

This gas-firedwater heater is design certified by the American Gas Association Laboratories under American

National Standards for Gas Water Heaters. The installa- tion must conform with this manual, Local Codes and with

I the latest edition of the National Fuel Gas Code, ANSI 7223.1.

This publication is available from your local government or public library, gas company, or by writing NFPA, Batterymarch Park, Quincy, MA 02269.

Read the "Safety Precautions" section, pages 2 through 4 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate

properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

°

This manual contains instructions for the installation, opera- tion, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ

THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this

manual; gas company rules; and Local Codes, or in the absence of Local Codes, with the latest edition of the National Fuel (]as code, ANSI Z223.1, also referred to as NFPA 54.

This publication is available from your local government or

public library or gas company or by writing NFPA, Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not

understand any portion o1: the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe instal- lation ate very important in preventing death from possible carbon monoxide poisoning and fires.

Examine the location to ensure the water heater complies with the "Facts to Consider About the Location" section in this

manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation proce- dures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street. Sacramento, CA 95814.

Product

Specifications

 

 

 

MODEL

TANK

 

TYPE

 

RECOVERY RATE

 

DIMENSIONS

IN INCHES

 

 

MINIMUM

 

HEIGHT TO

NUMBER

CAPACITY

OF

B.T.U.

GAI_. PER HOUR

VENT

 

 

1N GALLONS

GAS

RATE

@90*F RISE

PIPE

DIAMETER

JACKET TOP

153.332318

30

 

NATURAL

30,000

31.0

3,,

t6"

56"

153.332362

30

 

NATURAL

30,000

31.0

3"

16"

56"

153.332418

40

 

NATURAL

32,000

33.0

! 3"

18"

56½"

153.332462

40

 

NATURAL

32,000

33.0

3"

18"

56½"

153.332562

5O

 

NATURAL

32,000

33,0

3,,

20"

5672"

6

Page 6
Image 6
Kenmore 153.332362, 153.332462, 153.332418, 153.332318, 153.332562 Product Specifications, Customer Responsibilities

153.332562, 153.332362, 153.332418, 153.332462, 153.332318 specifications

The Kenmore series of air conditioners, specifically models 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362, stands out in the crowded market of home cooling solutions. Each model offers unique features and technologies designed to enhance user experience and comfort in varying environments.

One of the main features across these models is their impressive cooling capacity. Engineered for spaces ranging from small apartments to larger rooms, these units utilize advanced cooling technologies to ensure efficient heat exchange and optimal cooling performance. With SEER ratings often above 15, they not only provide powerful cooling but also contribute to energy savings, reducing electricity bills, and environmental impact.

In addition to cooling efficacy, Kenmore air conditioners prioritize user convenience. Most models in this series are equipped with programmable thermostats, allowing users to set schedules according to their daily routines. This feature ensures that the room maintains a comfortable temperature when needed while conserving energy during off-hours. Some models also support remote control operation via mobile apps, giving users the flexibility to adjust settings from anywhere in the home.

Noise levels are a critical consideration in air conditioning units, and the Kenmore series excels in this aspect. With advanced sound dampening technology, these air conditioners operate quietly, making them ideal for bedrooms, home offices, or other noise-sensitive environments. Users can enjoy a cool atmosphere without the disruption of loud machinery.

Maintenance is also simplified with features like washable and reusable air filters. These filters help to improve indoor air quality by capturing dust, allergens, and other particulates. Regular cleaning ensures that the unit functions efficiently and prolongs its lifespan.

Furthermore, the sleek design of Kenmore air conditioners allows them to blend seamlessly with modern home decor, offering both aesthetic appeal and functional cooling power. With various models catering to different room sizes and cooling needs, the Kenmore 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362 range provides versatile options for consumers looking for reliable and efficient air conditioning solutions. Overall, these units demonstrate Kenmore's commitment to quality and innovation in the HVAC market.