Troubleshooting Guide (cont'd)

Operational Conditions

(cont'd)

HIGH TEMPERATURE SHUT OFF SYSTEM

This water heater is equipped with an automatic gas shut offsys- tern. The high temperature shut offis built into the gas control valve. This system shuts off the gas supply to the water heater burners when high water temperatures are present. It is non- resettable, tf the high temperature shut off activates, the gas con- trol valve must be replaced. If this were to occur, turn "OFF" the entire gas supply to the water heater. Contact the Sears Service Center.

WATER IS TOO HOT

The temperature adjustment dial may be set too high. See the ' Temperature Adjustment section.

NOTE: A period of time is necessary after an adjustment has been made for the water temperature to reach the new tem- perature setting.

If lower temperature settings will not lower the water tempera- ture, call the Sears Service Center.

_,WARNING Shouldoverheatingoccuror the gassupply fail to shut off,

turn OFF the manualgascontrn valveto the app an€e,

NOT ENOUGH OR NO HOT WATER

:Check the manual gas shut offvalve to be sure it is open. Check the pilot flame. It may have gone out. All models have an opening behind the outer door for viewing the pilot.

If the pilot is not lit, follow the "Lighting" instructions in this manual are located above the gas control valve on the water heater to relight thepilot. If the water was extremely hot and is now cold, the high rJmit safety temperature shut off may have put out the burner and pilot. If the high temperature shut off activates, the gas controlvalve must be replaced. Contact the Sears Service Center.

The gas control knob must be turned to the "ON" position.

The temperature adjustment dial may be set too low. See the "Temperature Regulation" section.

The gas company can check the gas input to see if it is correct.

iAn underfired water heater will not heat water as quickly.

Look for leaking or open hot water faucets. Make sure all are closed.

The cold water inlet temperature may be colder during the

winter months. It will take longer to heat the water and seem like less hot water.

If you cannot find what is wrong, call the Sears Service Center.

AWARNING

HOTTER WATER CAN SCALD:Water heatersare intendedto producehot water. Water heated to a temperature whichwill satisfyclotheswashing,dishwashing,and other sanidzingneeds can scaldandpermanentlyinjureyou upon conta_ Some peo- ple are more likelyto be permanentlyinjuredbyhot water than other_ These includethe elder_, children,the inllrm, or physicaJ- ly/mentally handicappedIf. anyoneusinghotwater in yourhome fitsinto oneof these groupsor if there isa localcodeor state law requiringa certaintemperaturewater at she hot water ta_ then you must take specialprecaudon_In additionto usingthe lowest possibletemperature settingthat satisfiesyour hot water needs,

ameanssuchas a mixing valve,shouldbe usedat the hot water taps usedby these people or at the water heater. Mixingva/ves are availableat plumbingsupplyor hardwarestoreL Followman- ufatturers instructions for installation of the valves. Before

changing the factory setting on the thermostat, read the 'q'emperatureRegulation"sectionin this manual.

AWARNING

Due to the nature of the typical gas water heater, the water temperature in certain situations may be hotter

than the thermostat setting.

Short, frequent draws of hot water - especially with very ¢old incoming water - can shock the thermostat into brief operation resulting in hotter and hotter layers of water closer to the top of the tank.

Changes in hot water usage patterns or raising the tom- perature differential between the cut-on of the thermo- stat and the cold water temperature will usually eliminate

!the problem.

24

Page 24
Image 24
Kenmore 153.332562 Contd, High Temperature Shut OFF System, Water is TOO HOT, Not Enough or no HOT Water, Problem

153.332562, 153.332362, 153.332418, 153.332462, 153.332318 specifications

The Kenmore series of air conditioners, specifically models 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362, stands out in the crowded market of home cooling solutions. Each model offers unique features and technologies designed to enhance user experience and comfort in varying environments.

One of the main features across these models is their impressive cooling capacity. Engineered for spaces ranging from small apartments to larger rooms, these units utilize advanced cooling technologies to ensure efficient heat exchange and optimal cooling performance. With SEER ratings often above 15, they not only provide powerful cooling but also contribute to energy savings, reducing electricity bills, and environmental impact.

In addition to cooling efficacy, Kenmore air conditioners prioritize user convenience. Most models in this series are equipped with programmable thermostats, allowing users to set schedules according to their daily routines. This feature ensures that the room maintains a comfortable temperature when needed while conserving energy during off-hours. Some models also support remote control operation via mobile apps, giving users the flexibility to adjust settings from anywhere in the home.

Noise levels are a critical consideration in air conditioning units, and the Kenmore series excels in this aspect. With advanced sound dampening technology, these air conditioners operate quietly, making them ideal for bedrooms, home offices, or other noise-sensitive environments. Users can enjoy a cool atmosphere without the disruption of loud machinery.

Maintenance is also simplified with features like washable and reusable air filters. These filters help to improve indoor air quality by capturing dust, allergens, and other particulates. Regular cleaning ensures that the unit functions efficiently and prolongs its lifespan.

Furthermore, the sleek design of Kenmore air conditioners allows them to blend seamlessly with modern home decor, offering both aesthetic appeal and functional cooling power. With various models catering to different room sizes and cooling needs, the Kenmore 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362 range provides versatile options for consumers looking for reliable and efficient air conditioning solutions. Overall, these units demonstrate Kenmore's commitment to quality and innovation in the HVAC market.