1= Loosen or remove center terminal block screw.
2.Connect neutral wire (white or center wire) of power supply cord to the center,
BC
A. Neutral grounding wire (green with yellow stripes)
B. External ground conductor screw
C. Center
D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL Iisted strain relief
3.Connect the other wires to outer terminal block screws. Tighten screws.
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
Use where local codes permit connecting
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 31/2''(8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using
t'
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw.
1= Loosen or remove center terminal block screw.
2.Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
BC
/
/
• D
A. Neutral grounding wire (green with yellow stripes)
B. External ground conductor screw
C. Center
D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL Iisted strain relief
3.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
!!!!
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
Optional
Use for direct wire or power supply cord where local codes do not permit connecting
1.Remove center terminal block screw.
2.Remove neutral grounding wire (green with yellow stripes) from external ground conductor screw. Connect appliance ground wire and the neutral wire (white or center wire) of power supply cord/cable under center,
3.Connect the other wires to outer terminal block screws. Tighten screws.
!!!!
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
11