Power Supply Cord

Direct Wire

Fire Hazard

Use 10 gauge somidcopper wire.

Use a UL misted strain relief.

Disconnect power before making emectricamconnections.

Connect neutram wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 suppmy wires to remaining 2 termina_s (gored).

SecureBy tighten amlemectrical connections.

Failure to do so can resuJt in death, fire, or electrical shock.

3. Assemble a 3/,,,(1.9 cm) UL listed strain relief (UL marking on strain relief) into the hole below the terminal block opening. Tighten strain relief screws just enough to hold the two clamp sections together. Put power supply cord through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position.

4.

A. Terminal block cover

B. External ground conductor screw

C. Center, silver-colored terminal block screw

D. Hold-down screw location

E. Neutral grounding wire (green with yellow stripes)

Now complete installation following instructions for your type of electrical connection:

4-wire (recommended)

3-wire (if 4-wire is not available)

Page 8
Image 8
Kenmore 110.84182, 240-Volt Compact Electric Dryer manual Power Supply Cord Direct Wire