Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions provided with the vent system.

2.Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

Recommended hood styles are shown here.

B

AB

A. Over-The-Top installation (also available with one offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. For ordering information please call 1-800-4-MY-HOME ® (1-800-469-4663).

Over-The-Top Installation: Part Number 4396028

Periscope Installation (for use with dryer vent to wall vent mismatch):

Part Number 4396037 - for mismatch of 0" (0 cm) to 18" (45.72 cm)

Part Number 4396011 - for mismatch of 18" (45.72 cm) to 29" (73.66 cm)

Part Number 4396014 - for mismatch of 29" (73.66 cm) to 50" (127 cm)

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

..................

Determine vent length

1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible, Bend vent gradually to avoid kinking. Avoid 90 ° turns when possible.

(10.2 cm)

A.Louvered style B. Box hood style

The angled hood style (shown following) is acceptable.

See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.

Exhaust systems longer than specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

3.Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.

In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows.

Vent Length

Chart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

Number of

Type

of

 

Box

or

 

Angled

 

90 ° turns

vent

 

 

leuvered

 

hoods

 

or elbows

 

 

 

hoods

 

 

 

0

Rigid

metal

36

ft

(11 m)

26 ft (7.9

m)

 

Flexible

metal

28

ft

(8.5

m)

22 ft (6.7

m)

1

Rigid metal

26

ft

(7.9

m)

16 ft (4.9

m)

 

Flexible

metal

18

ft

(5.5

m)

12 ft (3.7

m)

2

Rigid

metal

16

ft

(4.9

m)

6 ft (1.8

m)

 

Flexible

metal

8 ft

(2.8

m)

2 ft (0.6

m)

1.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

2.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

3.Run vent to dryer location. Use the straightest path possible. See "Determine vent length." Avoid 90 ° turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.