Install Plastic Bypass Valve

Before installing the bypass valve, or copper tube, be sure the turbine and support are firmly in place in the valve outlet port.

Turbine

Sensor Port

Support

Turbine

FIG. 10

INSTALLING HOLDING CLIPS

Bypass Valve or

Black Clip

Cross Section of Valve

Inlet or Outlet

 

Installation Adaptor

 

 

 

O-Ring

Clip Snaps into Place

Between Larger Diameter Rings

FIG. 11

BYPASS VALVE TURNED DOWNWARD

Turn bypass valve upside down to connect to floor level plumbing.

OUT

IN

FIG. 12

Install 3-Valve Bypass

INSTALLING 3 VALVE BYPASS AND PIPES

3 VALVE BYPASS

Complete the following steps to install the three (3) valve bypass:

Cut the house main water pipe where you will con- nect the softener.

Loosely put together pipe, fittings, and the three

(3) valves.

Place valve(s) within easy reach.

When all pipe, fittings and valves make a good fit together, tighten all threaded joints (use pipe dope on outside threads), or solder all sweat joints.

TO

FIG. 13

Softener Inlet

 

Questions? Call The Kenmore Water Line 1-800-426-9345