Abbreviations Found In This Instruction Manual:

Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME ®.

They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers GAMA - Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA

Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).

Read the"Safety Precautions" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It

could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE A'n'EMPTING

TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.

Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.

 

 

 

 

 

 

RECOVERY

MINIMUM

 

DIMENSIONS

 

 

TANK

TYPE

 

RATE GALS.

VENT PIPE

DIAMETER

IN INCHES

(mm)

MODEL

 

CAPACITY

OF

BTU

PER HOUR

INCHES

INCHES

HEIGHT

TO

NUMBER

 

IN GALS (LTRS)

GAS

RATE

@ 90°F RISE

(mm)

(mm)

JACKETTOP

153336161

 

30

(114)

NATURAL

32,000

32.8

3" (76) or 4" (102)

18 1/2" (470)

433/4" (1,111)

153.336261

 

40

(151)

NATURAL

35,500

36.3

3" (76) or 4" (102)

20" (508)

47

1/4" (1,200)

153.336301

HA

30(114)

NATURAL

35,500

36.3

3"(76)

16"(406)

571/2"(1,461)

153.336361

 

30

(114)

NATURAL

35,500

36.3

3" (76)

16" (406)

57

1/2" (1,461)

153.336401

HA

40

(151)

NATURAL

35,500

36.3

3" (76)

18 1/2" (470)

55

1/2" (1,410)

153.336465

 

40(151)

NATURAL

35,500

36.3

3"(76)

181/2"(470)

551/2"(1,410)

153.336501

HA

50

(189)

NATURAL

35,500

36.3

3" (76)

20" (508)

56

1/2" (1,435)

153.336565

 

50

(189)

NATURAL

35,500

36.3

3" (76)

20" (508)

56

1/2" (1,435)

153.336761

 

30(114)

PROPANE

35,500

36.3

3"(76)

16"(406)

571/2"(1,461)

153.336801

HA

40(151)

PROPANE

35,500

36.3

3"(76)

181/2"(470)

551/2"(1,410)

153.336861

 

40(151)

PROPANE

35,500

36.3

3"(76)

181/2"(470)

551/2"(1,410)

153.336901

HA

50

(189)

PROPANE

35,500

36.3

3" (76)

20" (508)

56

1/2" (1,435)

153.336961

 

50

(189)

PROPANE

35,500

36.3

3" (76)

20" (508)

56

1/2" (1,435)

Page 5