Thislaundrycentermaybeconverted
toexhaustouttherightorleftside.To
convertthelaundrycenter,oneofthe
followingkitsMUSTbeused.
SideExhaustKitNo.3391335(white)
SideExhaustKitNo.3391336(almond)
Followtheinstructionsinthekitto
avoidoperationalandpersonalhazards.
Thesekitsareavailableatyourlocal
SearsstoreorSearsServiceCenter.
Typical instailations for left or right side
exhausting
DETERMINE VENT LENGTH
Maximum Exhaust Lengths:
Rear Exhaust. The maximum length
of the rear exhaust system depends
on the type of vent,the number of
elbows and the type of exhaust hood.
Refer to the chart below.
• Side ExhausL Side exhaust adds
a 90° turn inside the laundry center.
To determine maximum exhaust
length, add one 90° turn tothe chart.
EXHAUST HOOD TYPE
Numberof Maximum length of 4-inch
90°Turns diameter rigid heavy metalvent.
0 36fl. 34fl. 29ft.
1 26fl. 24fl. 2Oft.
2 16fl. 14fl. 12ft.
Numberof Maximum length of 4-inch
90°Turns diameterflexibleheavy metal vent
0 22fl. 21fl. 16ft.
1 16fl. 15fl. 10ft.
2 8ft. 7ft. 2ft.
NOTE: Avoid pushing the laundry center
tightly against a wall. This can crush or
kink the vent. Use the straightest path you
can, where possible, to avoid 90° turns.
29