STORAGE

STORAGE

Follow cleaning instructions A-D.

Remove the exhaust hose and window kit and repack the unit in its original shipping box. Store unit upright in a dry place where the temperature will remain above 35°F.

IMPORTANT: Always store and transport the unit so as to maintain the compressor in a upright orientation.

TECHNICAL SPECIFICATIONS

MODEL

408.72012

VOLTAGE

120V~60Hz

AMPERAGE:

 

COOLING

12 Amps

HEATING

10.5 Amps

 

 

POWER CONSUMPTION:

 

COOLING

1400W

HEATING

1200W

COOLING CAPACITY

12,000BTU/h

HEATING CAPACITY

12,000BTU/h

 

 

DEHUMIDIFYING CAPACITY(30ºC, RH80%)

126.8 Pints/Day (60 Liters/Day)

 

 

NOISE LEVEL (Indoor use)

53 dB(A)

AIR CIRCULATION (m3/h)

265 CFM maximum at high

fan speed

 

REFRIGERANT

R410A

 

 

REMOTE CONTROL

INCLUDED

 

 

TIMER

0-24h

 

 

DIMENSIONS (WxDxH)

21.7” x 12” x 29.9”/

55cm x 30cm x 76cm

 

NET WEIGHT

65 lbs/29.5 kg

 

 

TROUBLESHOOTING

If your air conditioner fails to operate, please follow these procedures prior to contacting customer service.

DO NOT ATTEMPT TO OPEN OR REPAIR THE AIR CONDITIONER YOURSELF. DOING SO WILL VOID THE WARRANTY AND CAUSE DAMAGE OR PERSONAL INJURY.

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

 

Can I turn the unit on immediately

 

No. The unit must be placed upright

after unpacking it?

 

for at least 12 hours after every

 

 

transport. Otherwise the compressor

 

 

may be damaged.

 

 

 

Unit does not start when pressing

Room temperature is higher

Lower the set temperature

power button

than the set temperature

 

 

(heating mode).

 

 

Room temperature is lower

Raise the set temperature

 

than the set temperature

 

 

(cooling mode).

 

 

 

 

The air conditioner does not

No electricity

Check house circuit breaker panel

come on

 

for tripped switch.

 

It is not plugged into the

Plug into outlet

 

outlet

 

 

The internal safety device

Wait 30 minutes; if problem persists,

 

has tripped

call 1-800-469-4663 to arrange for

 

 

product inspection and repair.

 

The safety device on the

Reset the safety plug

 

plug has tripped

 

 

 

 

The air conditioner works for only

There are bends or kinks in

Position the air hose correctly,

a short time

the air exhaust hose

keeping it as short and free of

 

 

curves as possiuble to avoid

 

 

bottlenecks.

 

Something is preventing the

Check and remove any obstacles

 

air from being discharged

obstructing air discharge.

 

 

 

Room is not cool enough

Windows/doors in room

Close all windows/doors

 

are open

 

 

There are heat sources

Remove heat source if possible

 

nearby

 

 

Exhaust hose is not

Connect the exhaust hose and make

 

connected or is blocked

sure it can function properly

 

Temperature setting is too

Decrease the set temperature

 

high

 

 

 

 

The air conditioner does not

Air filter blocked by dust

Clean the air filter

operate for about three minutes

The compressor control

Wait. This delay is part of normal

after restarting it

prevents the unit from

operation

 

being restarted until three

 

 

minutes have elapsed since

 

 

it was last turned off

 

 

 

 

Noise or vibrations

The floor is not level or the

Place the unit on a flat, level surface

 

unit is on an incline

 

 

 

 

Gurgling sound

The sound comes from

This is normal

 

the flowing of refrigerant

 

 

inside the air conditioner

 

 

 

 