Kenmore 580.75051 owner manual Installation Requirements Installation Hardware, Name Of Parts

Models: 580.75051

1 16
Download 16 pages 37.59 Kb
Page 5
Image 5
INSTALLATION REQUIREMENTS INSTALLATION HARDWARE

INSTALLATION REQUIREMENTS INSTALLATION HARDWARE

Your air conditioner will install into standard double

hung windows with actual clear opening widths of

22 to 36 inches (558mm to 914mm) (FIG. 1).

Lower sash must open sufficiently to allow a clear vertical opening of 14 inches (356mm). Side louvers and the rear of the air conditioner must have clear

air space to allow enough airflow through the condenser for heat removal. The rear of the unit

must be outdoors, not inside a building or garage.

14" min

Inner sill

Winddow

 

Offset

 

 

 

 

Sill

 

 

t

 

 

Exterior

 

 

FIG, I

ELECTRICAL SERVICE

Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on left side of cabinet).

All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your

ITEM

NAME OF PARTS

Q'TY

A

SHORT SCREW

11

B

WOOD SCREW

5

C

L BRACKET

3

D

FOAM STRIP

1

E

FOAM SEAL

1

F

SIDE CURTAIN

2

G

DRAIN PIPE

1

H

SUPPORT BRACKET

1

plug, call a qualified electrician to make the necessary corrections. SAVE CARTON and this OWNER'S MANUAL for future reference. The carton is the best

way to store unit during winter or when not in use.

IT:

To avoid risk of personal injury,propertydamage, or )roduct damage dueto the weight of this deviceand sharp edgesthat may beexposed:

Air conditionerscovered inthis manual pose an

excessiveweight hazard. Two or more peopleare neededto moveand installthe unit.

To preventinjury or strain, use properlifting and carryingtechniqueswhen movingunit.

Carefully inspect locationwhere air conditionerwill be installed. Besure it will supportthe weightof the unit over an extendedperiod of time.

Handle air conditionerwith care. Wear protective gloveswheneverlifting or carryingthe unit. AVOID the sharp metalfins of front and rearcoils.

Make sure air conditionerdoes not fall during installation.

-5-

REQUIRED TOOLS:

Tight Fitting gloves

Standard screwdriver

Phillips screwdriver

Pliers

Sharp knife

3/8-inch open end wrench or adjustable wrench

1/4-inch hex socket and ratcher

Tape measure

Electric drill

1/4-inch drill bit