OBSERVEALL LOCAL CODESAND ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,REMOVE
THE POWERSUPPLY CORD GROUND PRONG.
ELECTRICALGROUND IS REQUIREDON THIS APPLIANCE.
For 230/208volt 60 Hz,AC only, 15Afused and properlygroundedelectricalsupply is required.A time delay fuseor time delay circuit breaker is recommended.Usea dedicatedcircuit,servingonly thisappliance.
DO NOT USEAN EXTENSIONCORD.
115V~230V~
NOTE: The shape may be different according to its model.
RECOMMENDEDGROUNDINGMETHOD
Foryourpersonalsafety,thisappliancemustbegrounded. Thisappliancehasa powersupplycordwitha
Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.