Kenmore 580.75281 owner manual Ill DRAINAGE, Fig

Models: 580.75281

1 32
Download 32 pages 16.86 Kb
Page 7
Image 7
Ill DRAINAGE

_J Pull the bottom window sash down behind the upper guide until they meet.

NOTE:

Do not pull the window sash down so tightly that the movement of sliders is restricted. Attach the cabinet to the window inner sill by driving the screws (ITEM F) through the cabinet into window inner sill.

The cabinet should be installed with a very slight tilt downward by 1/4" from level.

Connect a drain elbow of 9/16" inside diameter to the drain pipe.

Connect a drain hose of 9/16" inside diameter to the drain elbow. (Drain hose is not supplied.)

Drain pipe

Drai'i

Window sash Ipper guide

elbowelbow

FIG. 13

Drain hose

Side curtain

ITEMF

_J_ Expand side curtains to fill opening.

FIG. 10

_"_ Slide the air conditioner into the cabinet. (FIG. 14) CAUTION: For security purposes, reinstall side screws that were removed in step 1.

Screw

Attach each side curtain to the window sash using 4 screws (ITEM G). (FIG. 11)

14

_]Cut the foam strip (ITEM K) to the proper length and insert between the upper window sash and the lower window sash. (FIG. 15)

_1_ Attach the window locking bracket (ITEM L) with a screw (ITEM G). See FIG. 12.

FIG. 12

FIG. 15

E]_ Adjust the vent before the decorative front is attached. (FIG. 16)

Straighten the lever, as shown. Pull down part (_to align with part (_.

Ill DRAINAGE

A drain hole is provided at the rear of the air conditioner unit. Refer to the drain method below:

• Remove the hole rubber from the basepan.

FIG. 16

-7-

Page 7
Image 7
Kenmore 580.75281 owner manual Ill DRAINAGE, Fig