SECTION 5 SERVICER'S TECH. INFORMATION
5A. TROUBLESHOOTING

KEEP THIS MANUAL WITH YOUR WATER SOFTENER. IF REPAIRS ARE NEEDED, THE SERVICE

TECHNICIAN MUST HAVE THE INFORMATION ON THE FOLLOWING PAGES.

24VAC

WIRING SCHEMATIC

NC
tt
NO
N
DOWN
UPbumm ,/
ON_DFF- HOUDburn SELECTimuan
ALWAYSMAKE THESEINmAL CHECKS FIRST
1. Doesthe time displayshowthe correct Ume ofday?.
...If display is blank, check power source to the
soRener.
...If time isflashing, powerwas off for over 6 hours.
Thesoftener resumes normaloperationbutregen-
erationsoccurat the wrongtime.
...If anerror code (Example:Err 03) showsin the face
plate display,go to AtJTO_C ELECTRONIC
DIAGNOSTICS.
2. Plumbing bypass valve(s) mustbe in Full Service
position.
3. Theinletand outletpipesmust connect tothe softener
inletand outletrespectively.
4. Isthe transformerpluggedintoa qive", groundedwall
outlet,and the power cablefastened securely?
z
5. The valve drainhose must befree of Idnksand sharp
bends,and notelevated over 8 ft. abovethe floor.
REMOVE THE TOPCOVER ANDSALT TANKCOVER

6. istheresaltinthestoragetank?

7. Is the brine tubing connected? (See water flow
diagrams).
8. Isthe brinevalve floatset right?(See page 22).
9, Pressthe SELECT button 2 times to displaythe
hardnesssetting.Besureitisthe correct settingforthe
households watersupply.(Make8hardnesstestof the
rawwaterandcompere withthe hardnesssetUng.Also
testa soft water sampieto verify ifa problemexlsts.]l
PressSELECT 3 times to ratumthe present time
display.
ffyoudonotitnd theproblemaftermakinginitialchecks,do
the MANUAL INmATED ELECTRONIC DIAGNOSTICS,
andthe MANUALADVANCE REGENERATION CHECK.
19