SECTION 5 SERV,CER'STECH.I.FOR.ATION
! I
5A. TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration
flow rates, and other controller functions. AL-
WAYS MAKE THE INITIAL CHECKS, AND THE
MANUAL INITIATED DIAGNOSTICS.
NOTE: The face plate display must show a
steady time (not flashing).
1. Press the ON/OFF-HOLD button and holdin
for 3 seconds. RECHARGE NOW beginsto
flash as the softener enters the fill cycleof
regeneration. Remove the brinewell cover
and, using a flashlight, observe fill water
entering the tank.
A. Ifit does not enterthe tank, lookfor an ob-
structed nozzle, venturi, flu flow plug, brine
tubing, or brine valveriser pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flOWto salt storage tank) 0.3 (1.1 liters)
BRINING _ .35 (1.3 liters)
BRINE RINSE /.22 (0.8 liters)
BACKWASH (flow to drain) 1.8 (6.8 liters)
FAST RINSE 1.8 (6.8 liters)
2. After observing fill, press the ON/OFF-HOLD
button to move the softener into brining. A
slow flow of water to the drain will begin.
Verify brine draw from the brine tank by
shining aflashlight into the brinewell and
observingano_ceable dropin the liquid level.
NOTE: Be sure a salt bridge is not preventing
water with salt contact.
A, If the softener does not draw brine...
...nozzle and/or venturi dirty ordefective.
...nozzle and ventufi not seated properly on
gasket.
...restricted drain (check drain fitting and
hose).
...defective nozzle and venturi seal.
...other inner valve defect (rotorseal, rotor &
disc,wave washer, etc.).
NOTE: If water system pressure is low, an
elevated drain hose may cause back pressure,
stopping brine draw.
3. Again press ON/OFF-HOLD to move the
softener intobackwash. Look for afast flow of
water from the drain hose.
A. An obstructedflow indicates aplugged back-
wash flow plug, drain hose, filter screen, or
topdistributor.
CAUTION: Do Not remove the top distributor
from the resin tank. Loss of water softening
resin will occur. See bottom of page 28.
4. Press ON/OFF-HOLD to move the softener
intofast rinse. Again look for a fastdrain flow.
Allowthe softener to rinsefor a few minutes to
flush out any brine that may remain in the
resintank from the brining cycle test.

5. To return the softener to service, press

ON/OFF-HOLD.

N

22