SECTION | 3 |
|
|
|
|
| CAREOFYOURSOFTENER | ||
t |
|
|
|
|
|
|
|
| 1 |
3B. | KEEPING THE WATER SOFTENER | CLEAN | |||||||
| COVERS |
|
| NOTE: |
|
|
| ||
To keep your new | Kenmore | water | softener looking | Never | use | cleaners having | ammonia or abrasives. | ||
nice, apply a coat of | paste wax and repeat | once a year. | They | may | scratch | and dull | the surface. | ||
When dusty, wipe | it with a damp | cloth | to keep it |
|
|
|
|
| |
sparkling. |
|
|
|
|
|
|
|
|
|
NOZZLE & VENTURI
A clean nozzle and venturi (FIG. 10) is a must for the
softener to work fight. This small unit moves brine from the salt storage tank to the resin tank during
regeneration. If it becomes plugged with sand, silt, dirt, etc., the softener will not work and you will get hard water.
To get to the nozzle and venturi, remove the softener top cover. Be sure the softener is in service cycle (no water pressure at nozzle and venturi), then turn off the cap from the nozzle and venturi housing. Do not lose
the large
the parts in warm water until clean. If needed, use a small brush to remove iron or dirt. Also check and
clean the gasket.
Carefully replace all parts in the correct order. Lubricate the
cap, by hand only. Do not overtighten and break the cap or housing.
IRON FROM THE RESIN BED
Your water softener takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some "clear water" iron. See maximum allowed in the specifications on page 20. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored. A water softener WILL NOT remove any iron which makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear
CLEANING THE NOZZLE &
VENTURI
v
Screen | Support | @ |
|
| Screen | / |
|
| ._. | "Flow Plug | |
|
| ||
| / | ||
Nozzle | & Venturi | _'_'_ |
|
| Gasket | _' | Screen |
|
|
|
IMPORTANT: Be sure small _'_=
holes in the gasket are cen-
tered directly over the small holes in the nozzle & venturi
housing,
*Flow Plug (HVDC)
Nozzle& Venturi
Housing
*install with numbered side up concave
side down. Be sure the largest flow plug is
located in the nozzle & venturi housing.
water iron, an iron filter or other equipment is needed. Your local Sears store has trained people to help you
with iron water problems,
If your water supply has clear water iron, even though less than the maximum allowed, regular resin bed cleaning is needed. Sears has resin bed cleaner, ltem No.
17