TROUBLESHOOTING

SECTION 5

SERVICE TECH INFORMATION

 

 

5A.

 

TROUBLESHOOTING

should

get a

reading

in the

display.

If you

get a

3. Press the #1 SELECT button and hold 3 seconds

reading,

unhook

the

in and out

plumbing

and

check

until...

the turbine for binding.

...SFaashows.

H; 2

 

o-"

MOTOR

 

 

 

POSITION SWITCH

SENSOR HOUSING

TURBINE

This code identifies the softener nominal capacity size. If the wrong number shows, the softener will operate

on incorrect programming. Do the following as needed.

TURBINE

SHAFT

VALVE

VALVE POSITION INDICATORS: Depending on the

valve position, the following indicators show in the display:

INDICATOR

VALVE

POSITION

Serv

service

Fill

fill

 

Brine

brining/brine rinse

Bkwash

backwash

Rinse

fast

rinse

When the valve is rotating from 1 cycle to another, both indicators flash. For example, if the valve is in transition between fill and brining, both Fill and Brine flash. Upon reaching brining position, Fill goes off and Brine is on steady. The time display shows the minutes of the cycle remaining.

NOTE: If the face plate is left in a diagnostic display

(or a flashing display when setting times or] hardness), present time automatically returns if a button is not pressed within 4 minutes. To return to

the diagnositc display, repeat step 2.

OTHER INFORMATION. While in this diagnostic screen, the following information is available and may be beneficial for various masons. This information is retained by the computer from the first time electrical power is applied to the face plate.

...Press [] to display the number of days this face plate has3_ad electrical Power applied.

...Press [_ to display the number of regenerations initiated by this face plate since the HF code number was entered.

HF32 does show -- Press the #1 SELECT button to return the present time display.

To

change

 

HF

number

-

Press

the

[]

or

[]

button

until

HF32

shows.

Then,

press

the

#1

SELECT button and reset the timer...page 6.

 

 

FACE PLATE REPLACEMENT: Be sure the valve

 

is

in

service

position

 

(observe

valve cycle

 

indicator)

 

when

replacing

the face

plate.

 

If, after installing

and

programming

the

replace-

 

ment

face

place,

the valve

_

in

service

posi-

 

tion, do the following to assure correct cycle

 

orientation,

 

or

timing,

between the face plate

 

and

valve.

 

 

 

 

 

 

 

 

 

 

Use

the MANUAL ADVANCE

procedures,

page

 

24.With the RECHARGE NOW button, advance through the recharge cycles until the valve stops

in service position, and RECHARGE no longer flashes in the timer.

NOTE: The valve motor may automatically drive through several valve positions while searching for service. If an error code occurs, unplug the transformer, then plug in again.

11"10NI

markers

(valve in service)

CAM

23

Page 23
Image 23
Kenmore 625.34867 owner manual Troubleshooting, 1110NI, Section, SFaashows, Service Tech Information