NOTE: If you ran the red reverse osmosis drain tubing directly to a remote drain point, disregard steps 5 and 6
and refer to instructions on page 10.
6. Mount the faucet body on to the faucet base, 1/4 turn.
FAUCET ELECTRONICS
The RO system will monitor the total product flow of the unit and also length of time the filters have been installed. The faucet base has an indicator light that
flashes to inform you of the status of the RO membrane and filters.
Green - RO membrane and filters are good.
Amber - Warning, filters need replacing. Filters need replacing, when water has been drawn, after 6 months time (or 650 gallons have been used).
Red - RO membrane needs to be replaced.
INSTALL BATTERY
When the coin battery is first applied at initial start up, the LED indicator light will flash in a red, amber, green sequence. All timers and counters are reset to zero. in
order to reset the time and gallon count feature, push the the button on the PWA and hold until the LED flashes
and release. The battery needs to be replaced at the time of filter replacement. Use only lithium batteries (CR 2032 or equivalent). Improper placement of battery could damage electronics. Use care when inserting the battery to align it correctly on PWA with the proper polarity. See Figure 15.
BLUE
3/8" quick connect fitting for the blue tube
PWA board
Battery /
BLACK TUBE
3/8" barb fitting for the black tube
UBE
1/4" barb fitting for the red tube
Figure 14
Reset button
Figure 15