Change collet

CHANGE COLLET AND O-RING

1.Remove the collet and o-ring from the fitting with a small screwdriver. Be careful not to scratch the inter-

nal walls of the collet port. See Figures 27 & 28.

2.Clean collet port, lubricate and insert the o-ring seal into the bottom of the port. See Figures 27 & 28.

3.Push the collet inward until it locks in place. See Figures 27 & 28.

Push o-ring seal into bottom of

 

 

 

port then follow with collet.

 

 

 

_/_

 

_}\1 Fitting

 

/ 0

O-Ring

Seal

 

Collet

 

 

 

Change collet

and

o-ring

Figure 27

Collet (depress to remove tubing)

CHANGE BATTERY

When the coin battery is first applied at initial start up, the LED indicator light will flash in a red, amber, green sequence. All timers and counters are reset to zero. In

order to reset the time and gallon count feature, push the the button on the PWA and hold until the LED flashes

and release. The battery needs to be replaced at the time of filter replacement. Use only lithium batteries (CR 2032 or equivalent). Improper placement of battery could damage electronics. Use care when inserting the battery to align it correctly on PWA with the proper polarity.

NOTE: It is not recommended that the RO assembly be opened, if this becomes necessary, pay careful attention to the layout of the parts and the routing of the tubing. it will be necessary to assemble the unit exactly as shown for the system to fit together and function prop- erly.

Disconnect

Tubing

Figure 28

PWA board

Reset button

Battery/

Figure 29

Figure 30

Questions? Call The Kenmore Water Line i-800-426-9345or visit KenmoreWater.com