- CARE OF YOUR REVERSE OSMOSIS SYSTEM -

PREFILTER AND POST FILTER CARTRIDGES

You must replace the pref!lter cartridge often to pro- tect the RO membrane from being destroyed by chlorine,

and/or from plugging with sediments in your water

supply. If the water supply contains both chlorine

and sediments, replace the prefilter cartridge at least

every 6 months of product water use. Replace more

often than 6 months if it begins to plug with sedi- ments.

If the water has sediments only, with no chlorine, you may notice a slower making of product water as the

prefilter collects the sediments. When this occurs, re-

timer. (monitor models).

*Note: Use a lubricant approved for use on a potable water supply.

prefilter

cartridge (cartridge o- ring seals on this end)

place the prefilter cartridge. Also replace the post f!lter cartridge.

To replace the filter cartridges (see Figure 12):

/

RO Cartridge

(cartridge o-ring seals on this end

1.Turn off the water supply and open the RO faucet to relieve pressure.

2.Remove (turn to the left) both sumps from the filter

heads. Be careful...the sumps are full of water.

3.Remove and discard the inner cartridges in a prop- er manner. Flush the insides of the sumps with fresh

water. Do not lose the large o-ring seals.

4.Insert new cartridges with o-ring* seals towards

the top, and with lubricated* o- rings in place, turn to the right to reattach the sumps.

5.Remove and replace batteries to reset counter and

o-ring seal

poetfilter

cartridge

(cartridge o-ring seals on this end)

sump

Turn sumps in the direction of the arrow to remove. Turn oppo- site way to install and tighten.

Figure 12

14

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Page 14
Image 14
Kenmore 625.385700, 625.385720 owner manual Care of Your Reverse Osmosis System, Prefilter and Post Filter Cartridges