- CARE OF YOUR REVERSE OSMOSIS SYSTEM -

TUBING CONNECTION (all push- in fitting locations)

This RO system includes push-in fittings for quick

tubing connection at most locations. If working with the fittings, do the following.

Connection (Figure 14):

1.Use a sharp cutter or knife to cut the end of tubing square.

2.Inspect the end (about 1") of the tubing to be sure

there are no nicks, scratches or other rough spots. If

needed, cut the tubing again.

3.Push tubing through the collet and all the way into

fitting. Full engagement is 11/16" for 1/4" tubing, and 3/4" for 3/8" tubing.

If using tubing other than tubing supplied with the

system, be sure it is of high quality, exact size and

roundness with a smooth surface.

Tubing correctly cut and connected

!

m

1

I

CAUTION

I

IDO NOT USE VINEGAR OR OTtIER ACID BASED I

ICLEANEI_,SON THIS F,OSYSTEM.THEY WILL I I r)EGRADESOMEI_,OSYSTEMPAP,TS.ALWAYS I

I

USE SOAP AN[)WATER.

I

!

m

m.I

This reverse osmosis system contains a replaceable treatment component critical to the efficiency of the

system. Replacement of the reverse osmosis compo- I I nent should be with one of identical specifications,

as defined by the manufacturer; to assure the same I

efficiency and contaminant reduction performance.

!

_

m.I

AUTOMATIC SHUTOFF SERVICE

If the shutoff assembly requires service, be sure to

reassemble parts exactly as shown in Figure 16.

cut tubing s_uare

II

I

end of tubing round and smooth, with no cuts,

nicks or fiat spots

Figure 14

collet ...__

_ 11/16" (1/4" tubing)

'engagement

_ 3/4" (3/8" tubing)

screw (4)

SHUTOFF

ASSEMBLY

diaphragm

o-ring

plunger

To Disconnect Tubing (Figure 15): Push the collet in- ward and hold with a finger while pulling the tubing out.

Changing Collet and O-ring (Figure 15):

1.With a small screwdriver remove the collet and o-

ring from the fitting. Be careful not to scratch the in- ternal walls of the collet port.

2.Be sure the port is clean, then lubricate and insert the o-ring seal to the bottom of the port.

3.Push the collet inward until it locks in place.

Replacing collet and

o-ring seal

collet (depress to

Push o-ring seal into

bottom

of port, then

remove tubing)

follow

with collet.

_--_fitting

tubi_/_

 

spring

 

valve

spacer ring

check

ball

 

diaphragm

 

collet

Figure 15

Figure 16

 

16

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Page 16
Image 16
Kenmore 625.385700, 625.385720 owner manual USE Soap Anwater, Automatic Shutoff Service, Changing Collet and O-ring Figure