Kenmore 721.80044, 721.80049, 721.80042 Wall Vented Installation, Step Prepare The Venting Blower

Models: 721.80044 721.80043 721.80042 721.80049

1 20
Download 20 pages 28.08 Kb
Page 11
Image 11
WALL VENTED INSTALLATION:

STEP 3:

PREPARE THE VENTING BLOWER

WALL VENTED INSTALLATION:

1.Remove one blower unit mounting screw and two blower plate screws. Remove the blower plate from cabinet. See Figure 12.

2.Carefully lift the blower unit out of the microwave oven. Disconnect the blower wire from connector. See Figure 13.

3.Use side cutters or tin snips to cut and remove knockouts "B" from Back plate. Discard knockouts. Be careful not to distort the plate. See Figure 14.

4.Rotate the unit so that the exhaust ports face the rear of the cabinet. See Figure 15. Before you insert blower unit, blower wire must be like

Figure 15.

5.Reassemble the blower wire into the connector.

_back plate

blower unit

blower plate mounting screws

Knockouts "B"

"%L.

blower plate blower unit mounting screw

Figure 12

.blower wire

6.Place blower unit back into cabinet. Check that the exhaust ports face towards the rear of the cabinet. See Figure 16.

7.Reattach the blower plate to the top of the cabinet as it was originally assembled. Attach with one blower unit mounting screw and then two blower plate mounting screws.

See Figure 17.

8.Go to STEP 4, PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION located on page 13.

Knockouts Parts "B"

Figure 14

exhaust ports

Figure 16

connector

Figure 13

blower unit

exhaust ports

Figure 15

blower plate mounting screws

Y

blower unit _.,_.._._%_ exhaust ports

blower unit

mounting screw

Figure 17

11

Page 11
Image 11
Kenmore 721.80044, 721.80049, 721.80042, 721.80043 Wall Vented Installation, Step Prepare The Venting Blower