ENSURING PROPER AIR CIRCULATION
In order to ensure proper temperatures, air must flow
between the refrigerator and freezer sections. As shown
in the illustration below, air enters at top of the freezer and
circulates down. From the bottom of the freezer, air is
forced up to the top of the refrigerator. Air enters
refrigerator through the top vent, then circulates and
exists at the bottom, where it returns to the freezer.
MULTI-FLOW
• Multi-Flow means powerful and effective cooling
operation. This is especially noticeable when new food is
placed in the refrigerator compartment.
• If water or foreign substances enter the cool air vent
while cleaning, efficiency will be lowered. In addition, if
gasket is damaged, efficiency may be lowered because
of escaping cool air.
Do not block any of cool air vents with food packages.
Ifthe vents are blocked, airflow will be interrupted and
temperature and moisture problems may occur.
IMPORTANT: Because air circulates between both
sections, any odors formed in one section will transfer to
the other. You must thoroughly clean both sections to
eliminate odors. To prevent odor transfer and drying out of
food, wrap or cover foods tightly. (See the Food Storage
Guide section for details.)
SETTING THE CONTROLS
• Your refrigerator has a control pad on the dispenser that
lets you regulate the temperature in the freezer and
refrigerator compartments.
• Initially set the REFRIGERATOR CONTROL at 37°F
(3°C) and the FREEZER CONTROL at 0°F (-18°C).
Leave it at this setting for 24 hours (one day) to stabilize.
Then adjust the compartment temperature as desired.
• Refrigerator Temp Control: 33°F to 46°F (0°C to 8°C)
The lower the number setting, the colder the refrigerator
compartment will become.
• Freezer Temp Control: -6°F to 8°F (-21°C to -13°C)
When the setting is at a lower number, the freezer
compartment becomes colder. The refrigerator
compartment becomes warmer because less cold a_r
flows into the refrigerator.
NOTE: If you want to change °F to °C or the reverse,
press and hold FREEZER key and REFRIGERATOR key
simultaneously for 5 seconds or more.
• Ultra Ice : Press the Ultra Ice button and the LED will
turn on. This function will remain activated for 24 hours
and increase the cooling speed of the freezer and the
amount of ice produced.
• Dispenser Lock :Press and hold the LOCK button for 3
seconds to lock the dispenser.
When it is locked, the dispenser will not operate. To
unlock, press and hold the LOCK button for 3 seconds.
• Filter Reset : When the FILTER RESET icon turns on,
you have to change the water filter. Press the FILTER
RESET button for 3 seconds to turn the icon off.
You need to change the water filter approximately every
6 months.
WARNING: If a door is open, the dispenser will not
work.
2O