Kenmore I 53.329463 40 GALLON Tank, Maximum Fuse, Minimum, Gals,Per, Hour, Liters, Lower

Models: 153.329265 38 GALLON SHORT 153.329264 38 GALLON SHORT I 53.329462 40 GALLON I 53.329863 80 GALLON I53.329562 55 GALLON 153.329362 30 GALLON I 52.329363 30 GALLON I 53.329862 80 GALLON I 53.329563 55 GALLON I 53.329463 40 GALLON I 53.329663 66 GALLON I 53.329662 65 GALLON

1 32
Download 32 pages 45.25 Kb
Page 5
Image 5
TANK

ThankYouforpurchasingSearswaterheaterProperly. installedandmaintained,it shouldgiveyouyearsoftrouble freeserviceItisstronglysuggestedthatthisnewwaterheater. beprofessionallyinstalled,contactthelocalSearsService CenteroranySearsstoreTheywillarrangeforprompt,quality. installationbySearsauthorizedcontractors.

Abbreviations Found In This Instruction Manual:

UL - Underwriters Laboratories Inc.

NEC - National Electrical Code

ANSI -American National Standards Institute

Read the "General Safety" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation,

operation, and maintenance of this electric water heater. It also contains warnings throughout the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few

pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this manual; electric company rules; and Local Codes, or in the

absence of Local Codes, with the current edition of the NEC - National Electrical Code, NFPA 70. This publication

is available from your local government or public library or

electric company or by writing Underwriters Laboratories

Inc., 333 Pfingsten Road, Northbrook, IL 60062.

If after reading this manual you have any questions or do

not understand any portion of the instructions, call Sears Service Center.

Carefully plan the place where you are going to put the water

heater. Correct electrical wiring and connections are very important in preventing death from possible electrical shock and fires.

Examine the location to ensure the water heater complies with the "Facts to Consider About the Location" section.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation procedures.

Instructions may be obtained from the California Office of the

State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed

in accordance with Massachusetts 248-CMR 2.00; State

Plumbing Code and 248-CMR 5.00. In the Commonwealth of

Massachusetts, this product must be installed by a licensed plumber or gasfitter.

 

TANK

 

DIMENSIONS

 

 

 

ELEMENT

 

MAXIMUM FUSE

 

 

 

RECOVERY

RATE

WATTAGE

MINIMUM

OR CiRCUiT

 

CAPACITY

 

IN INCHES (ram)

MODEL

 

GALS,PER

HOUR

@240

VOLTS

WIRE SIZE*

BREAKER

 

 

 

NUMBER

Gals

Liters

DIA.

HEIGHT

,@_90°FRise

UPPER

LOWER

{GAUGE)

SIZE (AMPS)

153.329264

38

I44

 

 

 

 

17.3

 

3800

3800

12

2O

153.329265

25.0

(635)

31.5

(800)

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

153.329362

30

114

 

 

 

 

I7.3

 

3800

3800

12

2O

153.329363

I9.0

(483)

47.0

(1,194)

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

153.329462

40

I51

 

 

 

 

17.3

 

3800

3800

12

2O

153.329463

I9.0

(483)

60.0

(1,524)

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

 

 

153.329562

55

208

 

 

 

 

17.3

 

3800

3800

12

2O

153.329563

21.5

(546)

61.0

(1,549)

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

 

 

153.329662

66

250

 

 

 

 

17.3

 

3800

3800

12

2O

153.329663

23.0

(584)

6I .0

(1,549)

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

153.329862

80

303

 

 

 

 

17.3

 

3800

3800

12

2O

153.329863

25.0

(635)

61.5

(1,562)

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.

Page 5
Image 5
Kenmore I 53.329463 40 GALLON, I53.329562 55 GALLON Tank, Maximum Fuse, Minimum, Gals,Per, Hour, Liters, Lower, Size Amps