FIG.19

FIG.19

/ STATUS LIGHTS

@ MAIN POWER

r_ CALL FOR HEAT C[RCUL_TORPUMP

@ GAS VALVE

BURNER

 

 

 

 

 

SYSTEM

STATUS

 

 

LIGHT

 

STATUS

 

 

 

 

 

 

 

INDICATES

 

 

ON

L7148F

CONTROL

ENERGIZED

THROUGH 24 VOLT TRANSFORMER.

POWER

 

 

 

 

 

 

 

 

 

 

 

 

OFF

L7148F

CONTROL

NOT

ENERGIZED.

 

 

CALL FOR HEAT/

ON

L7148F

CONTROL

ENERGIZING

CIRCULATOR

PUMP CIRCUIT.

CIRCULATOR

PUMP

OFF

CIRCULATOR

PUMP IS

NOT

ENERGIZED.

 

 

 

ON

L7148F

CONTROL

ENERGIZING

GAS CONTROL

VALVE (GAS VALVE OPEN)

GAS VALVE /

BURNER

 

 

 

 

 

 

 

 

 

 

 

 

OFF

GAS VALVE

NOT

ENERGIZED

(GAS VALVE CLOSED)

 

 

 

L7148F CONTROL LED ERROR CODES

 

LIGHT

 

STATUS

 

 

 

 

 

 

 

INDICATES

 

 

ON

L7148F

CONTROL

ENERGIZED

FULLY

FUNCTIONAL.

 

 

OFF

L714BE

CONTROL

NOT

ENERGIZED.

 

 

L7148F LED

STATUS

(2) BLINKS

SENSOR

ERROR (SHORTED

OR OPEN

SENSOR).

LIGHT

 

 

 

 

 

 

 

 

 

 

 

(3)BLINKS ANOLOG TO DIGITAL ERRORS (SET-POINT POT FAILURE).

(4)BLINKS RELAY FAILURE (CONTROL FAILURE)