- DIMENSIONS and SPECIFICATIONS -
15 _ | 13" |
|
|
|
|
|
|
|
|
|
|
|
| Metric | |
Supply | water | pressure | limits | 40 | - | 100 psi | 280 | - | 690 kPa | ||||
Supply | water | temperature | limits | 40 | - | 100 "F | 5 | - | 40°C | ||||
Maximum | total dissolved | soiids (TDS) | 2000 ppm |
|
|
| |||||||
Maximum | water | hardness | @ 6.9 pH |
| 10 gpg |
|
|
| |||||
Maximum | iron, | manganese, hydrogen sulfide |
|
| 0 |
|
|
| |||||
Chlorine |
| in water supply | (max. ppm) |
| 2.0 |
|
|
| |||||
Supply water pH limits (pH) |
| 4 - | 10 |
|
|
| |||||||
Product | (quality) water, 24 hours | f_ |
| 12 gal. | 45.42 liters | ||||||||
Waste water | per gallon | of product | water f]_, |
| 5 gal. | 18.9 | liters | ||||||
Percent | rejection of TDS, | minimum (new membrane) | (]? | 90 - 95 |
|
|
| ||||||
Storage | tank | capacity | (max.) |
| 2.3 | gal. | 8.7 liters | ||||||
Automatic | shutoff controi | ........................... |
| yes |
|
|
| ||||||
]i; feed water | supply | at 50 psi, 77 _F,and 750 TDS | Quality water production, | amount | of waste |
water and percent rejection all vary with changes in pressure, temperature and total dissolved solids.
16
Problems, Questions? Call