Kenmore Washer/Dryer owner manual THREE-WIREELECTRICAL Connection to Receptacle, Tothis conductor

Models: Washer/Dryer

1 66
Download 66 pages 62.44 Kb
Page 17
Image 17

I. THREE-WIREELECTRICAL

CONNECTION TO RECEPTACLE

Use a 3-wire power supply cord:

Fire Hazard

Use a new UL approved 30 ampere power supply cord.

Use a UL approved strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Local codes may permit the use of a U.L.-listed, 120/240-volt minimum,

30-ampere, dryer power supply cord kit (pigtail). Power supply cord should be type SRD or SRDT and be at least four feet long. The wires that connect to the laundry center must end with ring terminals or spade terminals with upturned ends.

Do not use an extension cord with this laundry center.

Do not connect plug end of power supply cord into a live receptacle before connecting power supply cord to laundry center terminal block.

The power supply cord must have three, No.-10 copper wires to match a three- wire receptacle of NEMA Type 10-30R.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to follow these instructions

can result in death, fire, or electrical shock.

UU

Thisbladeconnected

Neut_ral _.._:_,,_j

tothis conductor

3h-inch,U.L.-listed, strainreliel

Three-Wire Power Supply Cord

Spade terminals with upturned ends (OR ring terminals)

Connectwire with ends facing you

Ring terminals

(OR spade terminals)

Neutralwire (white)

Three-wire receptacle (NEMA TypelO-3OR)

17

Page 17
Image 17
Kenmore Washer/Dryer THREE-WIREELECTRICAL Connection to Receptacle, Tothis conductor, Ring terminals Or spade terminals