Kenmore Washer/Dryer owner manual II1. Make FOUR-WIRE Electrical Connection To Receptacle, Ring

Models: Washer/Dryer

1 66
Download 66 pages 62.44 Kb
Page 22
Image 22

II1. MAKE FOUR-WIRE

ELECTRICAL CONNECTION

TO RECEPTACLE

Use a 4-wire power supply cord:

Fire Hazard

Use a new UL approved 30 ampere power supply cord.

Use a UL approved strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or'bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to follow these instructions can result in death, fire, or electrical shock.

Local codes may permit the use of a U.L.-listed, 120/240-volt minimum, 30-ampere, dryer power supply cord kit (pigtail). Power supply cord should be type SRD or SRDT and be at least four feet long. The wires that connect to the laundry center must end with ring terminals or spade terminals with upturned ends.

For mobile homes or other four-wire installations, the power supply cord must have four, No.-lO copper wires and match a four-wire receptacle of NEMA Type 14-30R. The fourth wire (grounding conductor) must be identified with a green cover or bare copper wire and the neutral conductor by a white cover. Do not use an extension cord with

this laundry center.

Do not connect plug end of power supply cord into a live receptacle before connecting power supply cord to laundry center terminal block.

Neutralwire

Neutral3/+-inch,g.L.-listed,(white) strainrelief

 

Grounding

 

Grounding

wire (green)

Ring

prong

 

 

terminals

Four-Wire Power Supply Cord

 

(Mobile home or other four-wire installations)

 

Four-wire receptacle

1

 

(NEMA Type 14-30R)

 

22

i

Page 22
Image 22
Kenmore Washer/Dryer owner manual II1. Make FOUR-WIRE Electrical Connection To Receptacle, Ring