ELECTRIC DRYER ELECTRICAL CONNECTIONS

Connecting 4-Wire Connection: Direct Wire

Connecting Ground and Neutral Wires (cont.)

Connecting Remaining Wires

2.Connect ground and neutral wire to center terminal block.

4.Connect remaining wires to outer terminal block.

Connecting Direct Wire Ground

3.Connect ground wire (green or bare) with external ground connector screw.

Connecting 3-Wire Connection: Direct Wire

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer can be moved if needed.

Strip 312" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.

Connecting Neutral Wire

1.Loosen or remove center terminal block screw.

2.Connect neutral wire to center terminal block.

3.Connect remaining wires to outer terminal block.