Vent collar

DRYER VENTING REQUIREMENTS

Vent Hoods

4" (102 mm) Diameter Exhaust Hoods

Exhaust hood must be at least 12" (305 mm) from the ground

 

or any object that may be in the path of the exhaust (such as

 

flowers, rocks, bushes, or snow).

box hood

louvered hood

angled hood

12" min. (305 mm)

Vent System Length

Maximum Vent Length/Vent Connection

Maximum length of vent system depends upon the type of vent used, number of elbows, and type of exhaust hood.

Vent System Chart (Rigid Metal Vent)

No. of

Box and

Angled

90˚ Turns

Louvered Hood

Hood

0

135 ft. (41.2 m)

129 ft. (39.3 m)

1

125 ft. (38.1 m)

119 ft. (36.3 m)

2

115 ft. (35.1 m)

109 ft. (33.2 m)

3

106 ft. (32.3 m)

100 ft. (30.5 m)

4

98 ft. (29.9 m)

92 ft. (28.0 m)

For vent systems not covered by the vent specification chart, see your parts distributor.

Provision must be made for enough air for combustion and ventilation. (Check governing codes and ordinances.) See “Recessed Area and Closet Installation Instructions” in the “Stacked Washer/Gas Dryer Location” and “Stacked Washer/ Electric Dryer Location” sections.

A 4" (102 mm) outlet hood is preferred. However, a 212"

(64 mm) outlet exhaust hood may be used. A 212" (64 mm) outlet creates greater back pressure than other hood types. For permanent installation, a stationary vent system is required.

Connect Vent

1.If connecting to existing vent, make sure the vent is clean.

2.Using a 4" (102 mm) clamp, connect vent to exhaust outlet

in dryer.

3.Tighten hose clamp with Phillips screwdriver.

4.Make sure the vent is secured to exhaust hood with a 4" (102 mm) clamp.

5.Move dryer into final position. Do not crush or kink vent. Make sure dryer is level.

NOTE: Do not remove vent collar.