Maytag W10335465B Stacked WASHER/ELECTRIC Dryer Installation Requirements

Models: W10335465B

1 39
Download 39 pages 10.22 Kb
Page 11
Image 11

STACKED WASHER/ELECTRIC DRYER INSTALLATION REQUIREMENTS

Stacked Washer/Electric Dryer Location

Stacked washer/electric dryer installation clearances

n The location must be large enough to allow the washer and dryer doors to be fully opened.

n Additional spacing should be considered for ease of installation and servicing. The doors open more than 180°. The washer door is not reversible.

n Additional clearances might be required for wall, door, and floor moldings.

n Additional spacing of 1" (25 mm) on all sides of the washer/ dryer is recommended to reduce noise transfer.

n Companion appliance spacing should also be considered.

Selecting the proper location for your washer/dryer improves performance and minimizes noise and possible washer “walk.”

Your washer/dryer can be installed in a basement, laundry room, or recessed area. See “Drain System.”

Companion appliance location requirements should also be considered.

IMPORTANT: Do not install or store the washer/dryer where it will be exposed to the weather. Do not store or operate the washer/dryer in temperatures at or below 32°F (0°C). Some water can remain in the washer and can cause damage in low temperatures. Proper installation is your responsibility.

You will need:

nA water heater set to deliver 120°F (49°C) water to the washer.

nA grounded electrical outlet located within 6 ft. (1.8 m) of where the power cord is attached to the back of the washer. See “Electrical Requirements.”

nHot and cold water faucets located within 4 ft. (1.2 m) of the hot and cold water fill valves, and water pressure of 20–100 psi (137.9–689.6 kPa).

nA level floor with a maximum slope of 1" (25 mm) under entire washer/dryer. Installing the washer/dryer on soft floor surfaces, such as carpets or surfaces with foam backing, is not recommended.

nA sturdy and solid floor to support the washer/dryer with a total weight (water and load) of 450 lbs (204 kg).

nA floor drain under the bulkhead. Prefabricated bulkheads with electrical outlets, water inlet lines, and drain facilities should be used only where local codes permit.

Recessed Area and Closet Installation Instructions

This washer/dryer may be installed in a recessed area or closet. For recessed area and closet installations, minimum clearances can be found on the warning label on the rear of the dryer.

The installation spacing is in inches and is the minimum allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and ordinances.

If closet door is installed, the minimum unobstructed air opening in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.

The dryer must be exhausted outdoors.

48 in.2

 

(310 cm2)

3"

 

(76 mm)

Front

Closet

View

door

 

3"

 

(76 mm)

24 in.2

 

(155 cm2)

 

11

Page 11
Image 11
Maytag W10335465B Stacked WASHER/ELECTRIC Dryer Installation Requirements, Stacked Washer/Electric Dryer Location