Drain System
The washer can be installed using the
standpipe drain system (floor or wall), the
laundry tub drain system, or the floor
drain system. Select the drain hose instal-
lation method you need. (See "Alternate
Parts You May Need.")
I 2
Standpipe drain system -wall or floor
(view 1 & 2)
The standpipe drain requires a minimum
diameter standpipe of 2 in. (5 cm), The
minimum carry-away capacity can be no
less than 17gal (64 L) per minute, A2 in,
(5 cm) diameter to 1 in, (2.5 cm) diameter
standpipe adapter kit is available, (See
"Alternate Parts You May Need.")
The top of the standpipe must be at least
39 in, (99 cm) high and no higher than 96
in. (2.4 m) from the bottom of the washer.
Floor drain system (view 2)
The floor drainsystem requires asiphon
break that may be purchased separately.
(See "Alternate Parts You May Need.")
The siphon break must be a minimum of
28 in. (71 cm) from the bottom of the
washer, Additional hoses might be
needed.
Electrical Requirements

Electrical Shock Hazard

Plug into a grounded

3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these

instructions can result in

death, fire, or electrical shock.

• A 120-volt, 60-Hz., AC-only, 15- or 20-
ampere, fused electrical supply is
required. Time-delay fuse or circuit
breaker isrecommended. It is recom-
mended that a separate circuit serving
only this appliance be provided,
• This washer is equipped with a power
supply cord having a 3 prong ground
plug.
2
Laundry tub drain system (view 1)
The laundry tub needs a minimum 20gal
(76 L) capacity, Thetop ofthe laundry tub
must be at least 39 in. (99 cm)above the
floor and no higher than 96 in. (2.4 m)
from the bottom of the washer.