Kenwood CK 300 manual Conversion To Lpg, Injectors Replacement Of Top Burners

Models: CK 300

1 48
Download 48 pages 19.22 Kb
Page 35
Image 35
CONVERSION TO LPG

CONVERSION TO LPG

INJECTORS REPLACEMENT OF TOP BURNERS

If the injectors are not supplied they can be obtained from the “Service Centre”.

The diameter is marked on the injector in cents of millimetre.

Select the injectors to be replaced according to the “Table for the choice of the injectors” (page 36).

To replace the injectors:

Remove the gratings, the burner and the covers;

Using a wrench, substitute the nozzle injectors “J” (Fig. 10.3 - 10.4) with those most suitable for the kind of gas for which it is to be used.

The burners are conceived in such a way so as not to require the regulation of the primary air.

ADJUSTING OF THE MINIMUM OF THE TOP BURNERS

In the minimum position the flame must have a length of about 4 mm and must remain lit even with a quick turn from the maximum position to that of minimum.

The flame adjustment is done in the fol- lowing way:

Turn on the burner

Turn the tap to the MINIMUM position

Take off the knob

With a small flat screwdriver turn the screw inside the tap rod to the correct regulation (fig. 10.5).

Normally for LPG, tighten up the regula- tion screw.

J

Fig. 10.3

J

Fig. 10.4

Fig. 10.5

35

Page 35
Image 35
Kenwood CK 300 manual Conversion To Lpg, Injectors Replacement Of Top Burners, Adjusting Of The Minimum Of The Top Burners