Kenwood CK 300 Table For The Choice Of The Injectors, Cat II 2H3+, Nominal, Reduced, Burners

Models: CK 300

1 48
Download 48 pages 19.22 Kb
Page 36
Image 36
TABLE FOR THE CHOICE OF THE INJECTORS

GB

TABLE FOR THE CHOICE OF THE INJECTORS

Cat: II 2H3+

 

 

 

 

 

 

 

 

 

 

 

 

Nominal

Reduced

G 30 - 28-30 mbar

 

G 20

 

BURNERS

 

G 31 - 37 mbar

 

20 mbar

 

 

 

Power

Power

 

 

 

 

 

 

 

 

By-pass

Ø injector

Ring opening

By-pass

Ø injector

Ring opening

 

 

[kW]

[kW]

 

 

[1/100 mm]

[1/100 mm]

[mm]

[1/100 mm]

[1/100 mm]

[mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (A)

 

1,00

0,30

27

50

-

adjustable

72 (X)

-

 

 

 

 

 

 

 

 

 

Semi-rapid (SR)

1,75

0,45

32

65

-

adjustable

97 (Z)

-

 

 

 

 

 

 

 

 

 

 

Rapid (R)

 

3,00

0,75

42

85

-

adjustable

115 (Y)

-

 

 

 

 

 

 

 

 

 

Triple-ring (TR)

3,50

1,50

65

95

-

adjustable

135 (T)

-

 

 

 

 

 

 

 

 

 

 

Left Oven

 

3,70

0,75

42

92

fully open*

adjustable

140

5 *

 

 

 

 

 

 

 

 

 

 

Left Grill

 

2,50

-

-

80

fully open*

-

120

4 *

 

 

 

 

 

 

 

 

 

 

Right Oven

 

2,20

0,63

39

72

fully open*

adjustable

110

4 *

 

 

 

 

 

 

 

 

 

 

Right Grill

 

2,00

-

-

70

fully open*

-

105

2 *

 

 

 

 

 

 

 

 

 

 

*= Reference value

INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW)

BURNERS

Air necessary for combustion [m3/h]

Auxiliary (A)

2,00

 

 

Semi-rapid (SR)

3,50

 

 

Rapid (R)

6,00

 

 

Triple-ring

7,00

 

 

Left Oven

7,40

 

 

Left Grill

5,00

 

 

Right Oven

4,40

 

 

Right Grill

4,00

 

 