Kenwood CK 740 manual Lubrication Of The Gas Taps, Adjusting of the minimum of the top burners

Models: CK 740

1 48
Download 48 pages 10.47 Kb
Page 42
Image 42
2 - Adjusting of the minimum of the top burners

2 - Adjusting of the minimum of the top burners

In the minimum position the flame must have a length of about 4 mm and must remain lit even with a quick turn from the maximum position to that of minimum.

The flame adjustment is done in the following way:

Turn on the burner

Tum the tap to the MINIMUM position

Take off the knob

With a small flat screwdriver turn the screw inside the tap rod to the correct regulation (fig. 9.5).

Normally for LPG, tighten up the regulation screw.

Fig. 9.5

LUBRICATION OF THE GAS TAPS

If a tap becomes stiff, do not force; contact your local Service Agent.

 

GB

TABLE FOR THE CHOICE OF THE INJECTORS Cat: II 2H3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal

Reduced

G 30 - 28-30 mbar

 

 

G 20

 

BURNERS

 

 

G 31 - 37 mbar

 

20 mbar

 

 

 

 

Power

Power

 

 

 

 

 

 

 

 

 

 

By-pass

Ø injector

By-pass

Ø injector

 

 

 

 

[kW]

[kW]

 

 

 

 

[1/100 mm]

[1/100 mm]

[1/100 mm]

[1/100 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (A)

 

 

1,00

 

0,30

27

50

 

 

 

72 (X)

 

 

 

 

 

adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid (SR)

 

1,75

 

0,45

32

65

 

 

97 (Z)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (R)

 

 

3,00

 

0,75

42

85

 

 

 

115 (Y)

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple-ring (TR)

 

3,50

 

1,50

65

95

 

 

 

135 (T)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURNERS

 

 

 

 

Air necessary for combustion [m3/h]

 

 

Auxiliary (A)

 

 

 

 

 

2,00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid (SR)

 

 

 

3,50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (R)

 

 

 

 

 

6,00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

Triple-ring

 

 

 

 

 

7,00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 